TOPIC | 1.0 | Intro |
| 1.1 | Fri Aug 02 1996 11:39 | Top contributors to CLT::COBOL | 20 lines |
TOPIC | 2.0 | Mon Sep 09 1996 17:55 | COBOL application ports/migrations | 10 lines |
| 2.1 | Fri Nov 15 1996 05:21 | Oracle pre-compiler difference with >256 byte literals | 21 lines |
TOPIC | 33.0 | Report Writer |
| 33.8 | Wed Jan 04 1995 08:24 | NOVFC option is on the DEC COBOL for OpenVMS AXP wishlist | 8 lines |
TOPIC | 481.0 | Screen Section |
| 481.4 | Tue Mar 22 1994 14:17 | SCREEN SECTION now in DEC COBOL T2.0 | 4 lines |
TOPIC | 573.0 | Online Documentation Available |
| 573.20 | Thu Sep 14 1995 07:54 | V4.3 QRG is the last update available | 6 lines |
TOPIC | 930.0 | debugger needs more file record qualification |
| 930.2 | Sat Nov 05 1994 17:48 | Added to wishlist | 8 lines |
TOPIC | 1012.0 | Open error on collated index file |
| 1012.4 | Wed Nov 22 1995 17:57 | Yes - this is still on the wishlist | 8 lines |
TOPIC | 1400.0 | Object-oriented COBOL |
| 1400.5 | Wed May 12 1993 09:05 | 10-Mar-1993 - X3J4.1 Object-Oriented Extensions to COBOL | 6 lines |
| 1400.6 | Fri Sep 08 1995 09:37 | Dr. Dobb's Journal article (#235 Oct-1995) | 10 lines |
TOPIC | 1450.0 | COBOL compiler on Unix/Ultrix |
| 1450.5 | Mon Jul 15 1996 07:23 | See Compatibility Appendix - DEC COBOL User Manual | 11 lines |
TOPIC | 1617.0 | Wishlist for sys$flush on sequential files |
| 1617.2 | Wed Feb 22 1995 12:57 | DCOB$RMS_CURRENT_FAB/RAB are intended for things like $FLUSH | 8 lines |
| 1617.4 | Thu Feb 23 1995 06:19 | No current plans to port these routines to OpenVMS VAX | 14 lines |
TOPIC | 2078.0 | ex |
| 2078.1 | Wed Jan 29 1992 10:06 | Do CLOSE then another OPEN | 3 lines |
TOPIC | 2151.0 | Micro-focus COBOL -> VMS COBOL conversion ? |
| 2151.10 | Tue Mar 22 1994 14:38 | VAX/DEC COBOL support for features in .2 | 16 lines |
TOPIC | 2171.0 | Are alternate keys created? |
| 2171.1 | Mon May 11 1992 13:49 | See User Manual page 11-5 | 11 lines |
TOPIC | 2177.0 | COBOL and ISAM file access optimization suggestions needed. |
| 2177.1 | Mon May 18 1992 19:33 | Spread files across multiple disks | 3 lines |
TOPIC | 2228.0 | cobol 5.0 and move ? |
| 2228.4 | Mon Nov 07 1994 14:17 | MOVE w/ LINKAGE still a problem in VAX COBOL V5.2 | 14 lines |
| 2228.5 | Wed May 17 1995 10:16 | Fixed with T5.3-38 FT1 | 9 lines |
TOPIC | 2340.0 | Tue Dec 22 1992 08:16 | Unexpected RMS$_NORMAL from SYS$CREATE with VESTed VAX COBOL | 239 lines |
| 2340.1 | Tue Dec 22 1992 09:43 | Fixed in OpenVMS AXP V1.5 (DELTA) | 0 lines |
TOPIC | 2387.0 | segmented keys on alpha |
| 2387.1 | Tue Mar 09 1993 07:57 | No segmented key support in DEC COBOL V1.0 for OpenVMS AXP | 11 lines |
TOPIC | 2407.0 | DEC COBOL T1.0-651 Access Violation.. |
| 2407.2 | Mon Mar 29 1993 07:44 | Moved to CLT::DEC_COBOL_IFT note 93.* | 3 lines |
TOPIC | 2422.0 | HELP Reading Record Format stream-LF files |
| 2422.3 | Sat Apr 10 1993 19:27 | $ HELP CONVERT/FDL may be what you need | 25 lines |
TOPIC | 2427.0 | Need COBOL V3.3! |
| 2427.1 | Sun Apr 18 1993 09:30 | Does /STANDARD=V3 help somewhat? | 2 lines |
TOPIC | 2438.0 | CALL to PL/1 subroutines? |
| 2438.5 | Sun May 09 1993 10:14 | Make sure alignment and floating types match | 4 lines |
TOPIC | 2500.0 | SRCHNXTSEN on AXP but not VAX? |
| 2500.1 | Wed Jul 21 1993 08:15 | END-SEARCH and NEXT SENTENCE | 11 lines |
TOPIC | 2504.0 | Compiler access violates since upgrade to V5.0 |
| 2504.1 | Fri Jul 23 1993 18:51 | File protection violation | 2 lines |
TOPIC | 2525.0 | Find COBRTL version from .EXE file |
| 2525.1 | Wed Aug 18 1993 08:52 | You can find required COBRTL global section major/minor ID | 64 lines |
TOPIC | 2561.0 | AXP/VAX Compile times |
| 2561.2 | Wed Oct 13 1993 15:14 | Consider the use of /NOOBJ and /NOOPT | 13 lines |
TOPIC | 2574.0 | Infinite loop on ADD 1 in DEC COBOL V1.0-702 |
| 2574.1 | Tue Oct 26 1993 06:52 | Yes. Give us a pointer to the failing source file. | 2 lines |
TOPIC | 2590.0 | Can we do more than 18 packed decimal digits? |
| 2590.2 | Sat Nov 06 1993 08:15 | Use PL/I, BASIC, or RPG for >18 decimal digits | 10 lines |
TOPIC | 2594.0 | deferred-write for shared access |
| 2594.6 | Tue May 21 1996 10:19 | Doc update will be in VAX COBOL V5.4 | 7 lines |
TOPIC | 2618.0 | improperly handled condition calling LIB$ rtn |
| 2618.1 | Tue Nov 30 1993 07:49 | Try V1.0 /noopt or V1.1 | 3 lines |
TOPIC | 2619.0 | computation gives wrong results |
| 2619.1 | Tue Nov 30 1993 08:09 | Fixed with V1.1-747 | 6 lines |
TOPIC | 2634.0 | Alpha/COBOL Error Messages and Recovery Manual? |
| 2634.1 | Mon Dec 13 1993 07:16 | See CLT::DEC_COBOL_IFT notes 153,195 | 31 lines |
TOPIC | 2635.0 | dec cobol ? -> vax cobol v5.0 |
| 2635.5 | Mon Mar 14 1994 08:20 | DEC COBOL T2.0-200 available now | 3 lines |
TOPIC | 2643.0 | run-time error in COBRTL |
| 2643.1 | Tue Dec 28 1993 07:42 | I could not duplicate the failure | 32 lines |
TOPIC | 2656.0 | <COBOL 2.0 compiler problem?> |
| 2656.1 | Mon Jan 17 1994 06:58 | Try DEC COBOL V1.1-751 before submitting an Rdb SPR | 17 lines |
TOPIC | 2674.0 | misterious write after page |
| 2674.1 | Mon Jan 31 1994 07:23 | On OpenVMS systems, you are getting a VFC file | 4 lines |
| 2674.4 | Wed Feb 02 1994 08:43 | Avoid WRITE ADVANCING (WRITER AFTER PAGE) | 23 lines |
TOPIC | 2678.0 | Ref Site - Migration to Alpha AXP |
| 2678.2 | Mon May 23 1994 07:11 | See CLT::DEC_COBOL_IFT 312.1 | 7 lines |
TOPIC | 2684.0 | read previous on sequential files |
| 2684.1 | Wed Feb 09 1994 06:42 | No READ PREVIOUS for ORGANIZATION SEQUENTIAL | 14 lines |
TOPIC | 2689.0 | Undefined symbol DCOB$POW referenced? |
| 2689.1 | Mon Feb 21 1994 17:28 | What are the compiler/RTL versions in use? | 16 lines |
TOPIC | 2693.0 | File status / Vax / AXP |
| 2693.7 | Tue May 17 1994 13:56 | No plans for additional OpenVMS AXP V1.5 support | 17 lines |
TOPIC | 2695.0 | Q: XPG3&4 conformance of COBOL Offereings |
| 2695.2 | Sat Mar 05 1994 08:57 | DEC COBOL does NOT support X/Open sharing / locking | 10 lines |
TOPIC | 2708.0 | Primary and alternate starting in same position |
| 2708.1 | Fri Mar 18 1994 17:56 | Read prior is implemented in macro for use with VAX COBOL | 4 lines |
| 2708.3 | Sat Mar 19 1994 08:34 | I believe the routines work on OpenVMS VAX only | 11 lines |
TOPIC | 2712.0 | Known problems with COPY and logicals? |
| 2712.1 | Wed Mar 23 1994 21:17 | We need a COPY example and a .COM which defines the logicals | 13 lines |
| 2712.3 | Mon Mar 28 1994 17:44 | Can not duplicate - more information needed | 124 lines |
TOPIC | 2724.0 | DEC COBOL and library modules - /SEPARATE_COMPILATION |
| 2724.7 | Thu Jul 06 1995 22:24 | Under consideration for DEC COBOL V2.3 | 10 lines |
TOPIC | 2733.0 | %SYSTEM-F-ACCVIO on AXP with COBOL V1.1 |
| 2733.1 | Thu May 12 1994 14:44 | Thanks - I've copied the saveset | 2 lines |
TOPIC | 2735.0 | problem with /standard=v3 on axp |
| 2735.1 | Fri May 13 1994 11:50 | We need a program which shows this problem | 50 lines |
| 2735.3 | Tue May 31 1994 08:34 | Need a program other than the one in .1 | 16 lines |
| 2735.6 | Tue May 31 1994 11:37 | DEC COBOL matches VAX COBOL V5.2 for .1 (/STA=V3) | 34 lines |
| 2735.8 | Wed Jun 01 1994 08:07 | I can not reproduce the problem you report | 74 lines |
| 2735.10 | Wed Jun 01 1994 14:44 | Version of VAX COBOL User Manual and VAX COBOL RTL? | 26 lines |
TOPIC | 2736.0 | I need help on compiler status and futures |
| 2736.4 | Mon May 23 1994 00:11 | Try CLT::DEC_COBOL_IFT | 0 lines |
TOPIC | 2740.0 | kit cobol 1.1-754 vms/axp |
| 2740.1 | Tue May 31 1994 08:38 | See CLT::DEC_COBOL_IFT note 2 | 4 lines |
TOPIC | 2741.0 | Compile times for AXP vs. VAX COBOL compiles? |
| 2741.1 | Wed Jun 01 1994 00:24 | Data on 20K line COBOL program | 19 lines |
TOPIC | 2744.0 | 2 quick DEC & MF Cobol questions |
| 2744.1 | Wed Jun 01 1994 12:02 | DEC COBOL V1.1A is ANSI-85 compliant except for FUNCTIONs | 5 lines |
| 2744.3 | Wed Jun 08 1994 07:13 | DEC COBOL V2.0 w/ FUNCTIONs shipping now on OpenVMS AXP | 2 lines |
TOPIC | 2750.0 | high-order truncation of data items |
| 2750.5 | Wed Feb 19 1997 06:24 | low-order truncation; high-order truncation and /TRUNCATE | 85 lines |
TOPIC | 2751.0 | DEC COBOL and DECforms /ALIGN |
| 2751.1 | Mon Jun 06 1994 13:56 | Duplicate of note 2748? | 1 lines |
| 2751.6 | Tue Jun 07 1994 07:53 | DECforms and DEC COBOL compatibility | 21 lines |
| 2751.8 | Mon Jun 13 1994 07:44 | For DEC COBOL V2.0, use /NOALIGN and "using byte alignment" | 19 lines |
TOPIC | 2756.0 | Compiles with VAX COBOL, fails with DEC COBOL? |
| 2756.9 | Tue Jun 21 1994 07:57 | VAX COBOL and DEC COBOL produce the same diagnostic | 19 lines |
TOPIC | 2759.0 | compile performance question V1.1-747 |
| 2759.1 | Tue Jun 28 1994 17:59 | There is additional information in the release notes | 65 lines |
TOPIC | 2760.0 | IBM COBOL Truncates/Rounds Intermediate Results |
| 2760.1 | Thu Jun 30 1994 19:55 | Micro Focus and DEC COBOL match VAX COBOL | 26 lines |
TOPIC | 2771.0 | DEC COBOL version 2.1 ? |
| 2771.1 | Wed Jul 20 1994 08:07 | Details on DEC COBOL V2.1 | 39 lines |
TOPIC | 2774.0 | ACCVIO-AXP compiling |
| 2774.1 | Mon Jul 25 1994 08:45 | Fixed with V2.0-271 | 15 lines |
| 2774.3 | Wed Jul 27 1994 07:49 | CSDF14.AMS_NEW | 13 lines |
| 2774.5 | Mon Aug 08 1994 07:05 | You need to be using V2.0-271 or later | 2 lines |
| 2774.7 | Tue Aug 09 1994 21:21 | V2.0-271 started shipping 3 months ago | 3 lines |
TOPIC | 2780.0 | continuation lines and condition switch |
| 2780.1 | Mon Aug 08 1994 07:13 | VAX COBOL is working as intended | 29 lines |
TOPIC | 2781.0 | %GEM-F-ASSERTION, Ancestors passed to merge do not have same base symbol |
| 2781.1 | Mon Aug 08 1994 13:12 | Upgrade to V2.0-271 or later; source example needed | 13 lines |
| 2781.5 | Tue Aug 09 1994 21:17 | V2.0-271 is the supported solution | 19 lines |
| 2781.6 | Wed Aug 10 1994 00:55 | Try COBOL/OPT=LEV=1 | 8 lines |
TOPIC | 2789.0 | Random Error: Invalid Argument |
| 2789.1 | Sat Aug 20 1994 07:51 | Which compiler, RTL, OS versions are in use? | 5 lines |
| 2789.4 | Wed Aug 24 1994 00:02 | $ analyze/image | 17 lines |
TOPIC | 2790.0 | IS INITIAL + LBR$OUTPUT_HELP = %SYSTEM-F-OPCDEC |
| 2790.1 | Mon Aug 22 1994 19:23 | How are you resolving HLP$M_PROMPT? | 10 lines |
TOPIC | 2792.0 | AXP COBOL - path name for labels wrong. |
| 2792.6 | Tue Feb 14 1995 07:07 | Fixed with T2.2-648 | 4 lines |
TOPIC | 2794.0 | HELP! VAX & Alpha Cobol difference! |
| 2794.1 | Tue Aug 30 1994 13:53 | We'll need the source program | 21 lines |
| 2794.4 | Wed Sep 14 1994 09:31 | Does your output file print differently than expected? | 29 lines |
| 2794.6 | Wed Sep 14 1994 11:49 | See note 2726 | 2 lines |
| 2794.8 | Fri Sep 16 1994 15:57 | Possible COBOL options on OpenVMS AXP | 34 lines |
TOPIC | 2795.0 | %GEM-F-ASSERTION: CIL_COPY_TUPLE_TREE |
| 2795.1 | Wed Aug 31 1994 07:50 | I could not duplicate the problem | 2 lines |
| 2795.3 | Wed Aug 31 1994 13:54 | Still a problem with T2.1-509 | 2 lines |
| 2795.4 | Tue Oct 25 1994 12:49 | Fixed with V2.1-543 | 3 lines |
TOPIC | 2797.0 | Support of overpunch sign in PIC |
| 2797.1 | Thu Sep 01 1994 10:29 | Try removing COMP from SQLCODE | 10 lines |
TOPIC | 2799.0 | /DEBUG /OPTIMIZE problem |
| 2799.1 | Mon Sep 05 1994 08:53 | Problem on OSF and VMS with opt level 3 or higher | 22 lines |
| 2799.5 | Mon Sep 12 1994 07:23 | T2.1 FT4 for OpenVMS AXP kit coming 30-Sep | 6 lines |
TOPIC | 2800.0 | ISAM file accessed dynamically |
| 2800.1 | Tue Sep 06 1994 13:50 | Still a problem with latest RTL for OpenVMS AXP | 5 lines |
| 2800.5 | Sun Oct 30 1994 18:51 | Which behavior is most useful in real applications? | 8 lines |
| 2800.6 | Mon May 06 1996 17:52 | Behavior changed to match Digital UNIX with T2.4-101 DEC$COBRTL | 4 lines |
TOPIC | 2801.0 | V2.0-271 ASSERTION failure compiler bugcheck??? |
| 2801.1 | Wed Sep 07 1994 08:44 | Which version(s) of COBOL can successfully compile the program? | 32 lines |
| 2801.4 | Wed Sep 07 1994 20:48 | More info on VAX COBOL, DEC COBOL V2.0-271, T2.1-509 | 40 lines |
| 2801.6 | Thu Sep 08 1994 09:59 | INITCONFLICT is a different problem | 7 lines |
| 2801.10 | Tue Sep 27 1994 07:22 | Thanks | 6 lines |
TOPIC | 2804.0 | PB calling COBOL from C on AXP OpenVMS |
| 2804.1 | Wed Sep 14 1994 07:26 | The COBOL routine expects the arguments by reference | 13 lines |
TOPIC | 2805.0 | DBMS support option? |
| 2805.1 | Fri Sep 16 1994 09:50 | QL-355**-** is correct | 8 lines |
TOPIC | 2806.0 | Another /Optimize and /NoOptimize problem (from ACMS notes) |
| 2806.1 | Fri Sep 16 1994 07:41 | Try /OPT=LEV and /CHECK | 20 lines |
TOPIC | 2808.0 | VMS Cobol to OSF/1 ??? |
| 2808.1 | Wed Sep 21 1994 16:24 | See Section 1.6 in the OSF release notes | 4 lines |
TOPIC | 2810.0 | COBOL-F-BUG_CHECK on AXP |
| 2810.1 | Wed Sep 21 1994 16:26 | CLT::DEC_COBOL_IFT note 353 | 0 lines |
TOPIC | 2813.0 | %GEM-F-ASSERTION, HIST_MULTIPLE_REGS CORRUPTED error |
| 2813.1 | Mon Sep 26 1994 14:18 | See CLT::DEC_COBOL_IFT note 327 | 5 lines |
| 2813.5 | Wed Sep 28 1994 16:56 | V2.1 for OpenVMS AXP - SSB 02-Nov-1994 | 7 lines |
TOPIC | 2814.0 | SQLPRE/COBOL (DEC COBOL) error |
| 2814.1 | Tue Sep 27 1994 07:31 | We need the source and include files | 16 lines |
| 2814.3 | Thu Sep 29 1994 07:00 | COPY to CLT::/PROT=WO:RWED | 9 lines |
TOPIC | 2816.0 | Move varies on VAX and AXP |
| 2816.3 | Tue Oct 04 1994 07:59 | V2.1 for OpenVMS AXP goes to the SSB 02-Nov | 17 lines |
TOPIC | 2817.0 | error in calculation on AXP |
| 2817.1 | Tue Oct 04 1994 08:47 | Still a problem with T2.1-526 | 4 lines |
| 2817.3 | Wed Oct 05 1994 07:17 | One possible solution under evaluation now | 7 lines |
| 2817.4 | Sun Oct 09 1994 08:00 | Move from DEC_COBOL_IFT | 32 lines |
| 2817.5 | Sun Oct 09 1994 08:14 | No solution yet | 2 lines |
| 2817.7 | Wed Oct 26 1994 06:13 | Improvements in intermediate result precision - after V2.1-543 | 26 lines |
| 2817.8 | Wed Nov 30 1994 19:50 | Fixed with V2.1-613 | 72 lines |
TOPIC | 2820.0 | Link creates 73K EXE |
| 2820.1 | Thu Oct 06 1994 09:38 | Use LINK/MAP and compare included modules | 9 lines |
TOPIC | 2823.0 | low values comparison failing V2.0 |
| 2823.1 | Mon Oct 10 1994 13:08 | Use /CHECK=DECIMAL | 34 lines |
TOPIC | 2826.0 | accvio dec cobol 2.0 (ovms axp 6.1).Report writer? |
| 2826.5 | Tue Oct 18 1994 09:44 | Field test kit may given to licensed field test sites only | 8 lines |
| 2826.7 | Mon Oct 24 1994 07:30 | V2.1-543 SSB network kit TUE 25-Oct | 5 lines |
| 2826.9 | Mon Oct 24 1994 18:20 | See CLT::DEC_COBOL_IFT | 4 lines |
TOPIC | 2831.0 | New problem with COMP-2 and exponentiation |
| 2831.10 | Fri Nov 04 1994 12:49 | What version of OpenVMS VAX does the customer have? | 19 lines |
| 2831.13 | Wed Nov 09 1994 08:36 | Yes. TIMA kit planned. | 7 lines |
| 2831.16 | Mon Jan 30 1995 12:51 | No VAX COBOL RTL TIMA kit yet | 6 lines |
| 2831.18 | Mon Jan 30 1995 14:44 | Which image? | 4 lines |
| 2831.20 | Mon Jan 30 1995 19:14 | ANA/IMAGE output needed | 2 lines |
| 2831.22 | Tue Jan 31 1995 12:19 | Use CLT::CLT$LIBRARY:[C79NET]COBRTL.EXE;8 (27-Oct) | 10 lines |
TOPIC | 2833.0 | cobol/decforms alignment on axp |
| 2833.1 | Fri Oct 21 1994 08:08 | No fix yet to /ALIGN padding problem | 18 lines |
TOPIC | 2834.0 | %SYSTEM-F-ACCVIO, AXP 6.1, COBOL 2.0 |
| 2834.1 | Fri Oct 21 1994 08:22 | More parts of the source file needed | 5 lines |
| 2834.2 | Sat Oct 22 1994 18:09 | Fixed with T2.1-474 FT2 | 155 lines |
| 2834.3 | Mon Oct 24 1994 08:17 | COMVAR.LIB received - test still runs fine | 2 lines |
TOPIC | 2835.0 | WRONG DISPLAY COMPILE WITH /DEBUG/NOOPT AXP6.1 C2.0 |
| 2835.1 | Fri Oct 21 1994 08:18 | Fixed with T2.1-526 FT4 | 11 lines |
TOPIC | 2837.0 | BUG_CHECK on DISPLAY but only in BATCH |
| 2837.1 | Mon Oct 24 1994 10:26 | Still a problem in batch with V2.1-543 | 5 lines |
| 2837.4 | Thu Jan 05 1995 17:43 | Fix is in RTL - DEC$COBRTL.EXE V2.1-139 | 14 lines |
| 2837.6 | Fri Jan 06 1995 07:20 | See .4 | 5 lines |
| 2837.8 | Fri Jan 27 1995 14:19 | See CLT::DEC_COBOL_IFT 9.22 | 7 lines |
| 2837.14 | Sun Mar 05 1995 23:34 | The kit referenced in .8 can be given to customers | 22 lines |
| 2837.18 | Mon Feb 12 1996 09:51 | You need DEC COBOL V2.3 | 20 lines |
| 2837.19 | Tue Feb 13 1996 14:46 | COBOLRTL023 can be installed independently of COBOL023 | 58 lines |
TOPIC | 2838.0 | Communication with cash registers |
| 2838.1 | Tue Oct 25 1994 10:59 | LINE SEQUENTIAL supported in DEC COBOL V2.0 for OpenVMS AXP | 25 lines |
TOPIC | 2839.0 | dash/hyphen and underscore confusion in debugger |
| 2839.1 | Thu Oct 27 1994 09:52 | I believe this is still a problem with OpenVMS AXP DEBUG | 5 lines |
| 2839.3 | Thu Mar 23 1995 07:32 | I again asked the DEBUG people for an update | 10 lines |
| 2839.4 | Sun Oct 08 1995 11:53 | Problem now under investigation by OpenVMS Alpha DEBUG | 16 lines |
| 2839.5 | Fri Apr 05 1996 15:33 | Fixed in Gryphon release of OpenVMS Alpha DEBUG | 3 lines |
| 2839.6 | Wed Aug 21 1996 09:21 | DEBUG kit available | 112 lines |
TOPIC | 2842.0 | (!AC) *CDD error at node !AS |
| 2842.1 | Mon Oct 31 1994 11:52 | CDD record definition needed | 2 lines |
| 2842.4 | Mon Oct 31 1994 16:12 | COBOL/DEPENDENCY_DATA would try to write to CDD | 7 lines |
| 2842.7 | Wed Nov 02 1994 11:03 | VAX COBOL V5.1 should be using READ_ONLY transactions | 12 lines |
| 2842.10 | Thu Nov 03 1994 14:56 | COBRTL should not be involved with this problem | 9 lines |
| 2842.18 | Mon Dec 12 1994 14:16 | How is CDD$DICTIONARY defined? | 9 lines |
TOPIC | 2845.0 | Thu Nov 03 1994 17:33 | DEC COBOL kits and docs | 4 lines |
| 2845.1 | Fri Mar 24 1995 07:10 | DEC COBOL T2.2-662 FT2 | 1 lines |
| 2845.2 | Thu Apr 20 1995 11:04 | DEC COBOL V2.2-674 SSB | 2 lines |
| 2845.3 | Fri Aug 18 1995 15:47 | See CLT::DEC_COBOL_IFT note 2.30 for DEC COBOL T2.3-723 FT1 | 0 lines |
| 2845.4 | Thu Oct 26 1995 17:24 | See CLT::DEC_COBOL_IFT note 2.35 for DEC COBOL T2.3-779 FT2 | 0 lines |
| 2845.5 | Thu Dec 07 1995 15:59 | See CLT::DEC_COBOL_IFT note 2.38 for DEC COBOL V2.3-793 SSB | 0 lines |
| 2845.7 | Mon Jul 15 1996 07:26 | Keyword DOC added to note 2 in DEC_COBOL_IFT | 5 lines |
TOPIC | 2846.0 | Formal argument overloaded with return value - legal?? |
| 2846.3 | Mon Nov 14 1994 06:11 | DEC COBOL will never be 100% compatible with VAX COBOL | 7 lines |
| 2846.11 | Tue Nov 29 1994 14:23 | Fixed with V2.1-614 | 6 lines |
TOPIC | 2849.0 | program (on AXP) /detach gets 2 output files! |
| 2849.6 | Sun Oct 08 1995 12:00 | Fixed with T2.3-62 DEC COBOL RTL | 7 lines |
TOPIC | 2860.0 | RMS-FILENAME badly initialized search list logical |
| 2860.1 | Tue Nov 29 1994 06:48 | Fails w/ VAX COBOL V5.2; OK with DEC COBOL V2.1 | 16 lines |
TOPIC | 2861.0 | ACCEPT ... AT END clause ignored on VAX |
| 2861.1 | Wed Nov 30 1994 07:07 | Workarounds | 8 lines |
| 2861.3 | Thu Dec 01 1994 05:24 | Use of QAR system eliminated | 10 lines |
TOPIC | 2863.0 | is the cobol v2.1 compiler for axp available now? |
| 2863.2 | Wed Nov 30 1994 07:24 | DEC COBOL V2.1 is shipping now | 52 lines |
TOPIC | 2865.0 | Does DECCOBOL V2.1 for OSF/1 support user based licencing? |
| 2865.1 | Wed Nov 30 1994 18:02 | DEC COBOL V2.1-509 is the correct product version | 8 lines |
TOPIC | 2868.0 | eats the COBRTL on AXP 6.1 too much memory? |
| 2868.7 | Thu Jan 19 1995 17:16 | See CLT::DEC_COBOL_IFT 9.22 | 1 lines |
TOPIC | 2869.0 | V5.2 value-list compiler bug |
| 2869.1 | Tue Dec 06 1994 07:14 | Fails with VAX COBOL; OK with DEC COBOL | 8 lines |
TOPIC | 2870.0 | External and record format? |
| 2870.1 | Tue Dec 06 1994 12:03 | Can you create the file you want with a non-EXTERNAL FD? | 32 lines |
TOPIC | 2871.0 | Wed Dec 07 1994 09:58 | DEC COBOL and Liant's Relativity for OpenVMS | 86 lines |
| 2871.1 | Thu Dec 08 1994 10:13 | Another recent reference to Liant | 183 lines |
TOPIC | 2872.0 | COBOL & ALPHA: similar problems as PENTIUM? |
| 2872.1 | Wed Dec 07 1994 15:58 | Fixed with V2.1-613 | 1 lines |
TOPIC | 2873.0 | cobol V2.1-543, vms V6.1 - compile ACCVIO |
| 2873.2 | Thu Dec 08 1994 08:57 | Let me try one of the customer ACCVIOs on our system | 13 lines |
| 2873.4 | Thu Dec 08 1994 18:09 | Example which fails on our systems needed | 5 lines |
| 2873.6 | Fri Dec 09 1994 08:34 | ACCVIO compiling AISM_ENQ_DEQ_MENU_LOCK | 25 lines |
| 2873.7 | Fri Dec 09 1994 12:12 | Problem compiling a MOVE statement | 9 lines |
| 2873.15 | Wed Jan 11 1995 07:04 | Suggested workaround is temporary until we fix the problem | 5 lines |
| 2873.19 | Wed Feb 22 1995 08:03 | Fixed with T2.2-651 | 20 lines |
TOPIC | 2875.0 | VAX COBOL to DEC COBOL Migration |
| 2875.1 | Fri Dec 09 1994 06:20 | Yes - see the DEC COBOL V2.1 release notes | 21 lines |
| 2875.3 | Fri Mar 22 1996 06:05 | Evaluate the VAX COBOL extensions used by the applications | 13 lines |
TOPIC | 2876.0 | /INST=NODEC problem in COBOL V5.1 |
| 2876.1 | Tue Dec 13 1994 08:55 | Complete source example showing problem needed | 32 lines |
| 2876.4 | Wed Dec 14 1994 06:44 | Problem back to at least VAX COBOL V4.4 | 12 lines |
| 2876.6 | Thu Dec 15 1994 06:43 | /INST=DECIMAL versus /INST=NODECIMAL | 24 lines |
| 2876.7 | Fri Dec 16 1994 01:31 | Additional workaround | 23 lines |
| 2876.14 | Sat Apr 29 1995 08:19 | Fixed with 28-Apr-1995 COBRTL.EXE | 6 lines |
TOPIC | 2877.0 | Question on file versions on open output |
| 2877.1 | Tue Dec 13 1994 10:16 | Programmer given flexibility in using OpenVMS file versions | 19 lines |
TOPIC | 2878.0 | bas$edit error |
| 2878.1 | Wed Dec 14 1994 07:46 | Use COBOL/TIE and LINK/NONATIVE_ONLY | 60 lines |
TOPIC | 2879.0 | -W-IGNUNKDIR compiling with/ANSI_FORMAT on AXP |
| 2879.1 | Fri Dec 16 1994 09:36 | Source comments of the form *DC should be changed | 18 lines |
TOPIC | 2880.0 | Compatibility Book VAX and AXP |
| 2880.1 | Mon Dec 19 1994 20:26 | Some items added to DEC COBOL after the V1.0 compatibility manual | 36 lines |
TOPIC | 2885.0 | Reading Backwards thru RMS... |
| 2885.1 | Wed Jan 04 1995 08:41 | Yes - in DEC COBOL V2.x | 7 lines |
| 2885.3 | Fri Jan 06 1995 07:23 | RMS supports the features both OpenVMS platforms | 8 lines |
TOPIC | 2886.0 | Strangeness opening a file across the net - axp->vax |
| 2886.10 | Thu Mar 30 1995 18:58 | There is no additional update beyond .7 | 8 lines |
| 2886.11 | Sun Oct 08 1995 08:41 | Use F$PARSE to see how filespecs are contructed on OpenVMS | 39 lines |
TOPIC | 2889.0 | Code not running after 4.3 to 5.1 upd |
| 2889.2 | Fri Jan 13 1995 14:38 | What happens if the programs are NOT re-compiled? | 7 lines |
| 2889.5 | Mon Jan 16 1995 21:48 | I could not reproduce a difference | 140 lines |
TOPIC | 2891.0 | Tue Jan 17 1995 11:12 | Request for VAX/DEC COBOL field test sites | 59 lines |
| 2891.1 | Sat Apr 08 1995 10:07 | VAX COBOL T5.3 field test starts 26-May | 26 lines |
| 2891.2 | Sat Aug 12 1995 09:06 | DEC COBOL T2.3 | 35 lines |
| 2891.3 | Sun Apr 07 1996 08:43 | VAX COBOL T5.4 and DEC COBOL T2.4 | 56 lines |
| 2891.4 | Tue Jul 02 1996 20:17 | More details on DEC COBOL T2.4 FT1 | 65 lines |
| 2891.5 | Wed Oct 09 1996 23:27 | VAX COBOL T5.4 field test starts 15-Nov-1996 | 230 lines |
TOPIC | 2892.0 | EVALUATE FUNCTION compile ACCVIO and wrong results |
| 2892.3 | Thu Jan 19 1995 07:24 | Problem duplicated on our systems | 8 lines |
| 2892.4 | Thu Jan 19 1995 09:44 | Problem is with EVALUATE with PERFORM | 69 lines |
| 2892.5 | Sun Jan 22 1995 09:06 | EVALUATE FUNCTION compile ACCVIO | 39 lines |
| 2892.6 | Wed Jan 25 1995 11:01 | EVALUATE FUNCTION wrong results | 6 lines |
| 2892.7 | Thu Jan 26 1995 07:55 | Fixed with T2.2-642 | 4 lines |
TOPIC | 2893.0 | Access violation on compile after upgrade |
| 2893.1 | Fri Jan 20 1995 06:21 | Fixed with VAX COBOL V5.2 | 7 lines |
TOPIC | 2895.0 | AXP COBOL COB-F-BUGCHECK patch |
| 2895.1 | Mon Jan 23 1995 07:20 | Use the latest RTL kit | 11 lines |
TOPIC | 2897.0 | COMP-2 problem on Alpha |
| 2897.1 | Mon Jan 30 1995 13:00 | I could not duplicate this difference | 18 lines |
| 2897.5 | Fri Jun 23 1995 15:21 | Post examples of differences between VC V5.2 and DC V2.2 | 18 lines |
TOPIC | 2899.0 | BADLOGIC with EVALUATE & COBOL 5.2 |
| 2899.3 | Wed Feb 01 1995 12:09 | Complete source needed | 27 lines |
| 2899.5 | Thu Feb 02 1995 10:21 | Workaround - use temporary for 7th EVALUATE condition | 241 lines |
TOPIC | 2900.0 | Has COBOL 5.2 been tested on OpenVMS 6.1? |
| 2900.2 | Fri Feb 03 1995 15:21 | Yes - tested with both DECnet Phase IV and OSI | 17 lines |
| 2900.4 | Wed Feb 08 1995 18:09 | Testing information in this note relates to VAX COBOL V5.2 | 7 lines |
TOPIC | 2901.0 | ACCVIO compiling porgram that access CDD |
| 2901.1 | Fri Feb 03 1995 08:44 | Could you post the COBOL/LIS/COPY .LIS file | 6 lines |
| 2901.8 | Wed Feb 22 1995 08:06 | Fixed with T2.2-651 | 14 lines |
| 2901.10 | Tue Oct 03 1995 07:38 | Probably fixed with T2.3-735 | 22 lines |
| 2901.14 | Thu Oct 05 1995 11:11 | I could not duplicate this failure | 8 lines |
TOPIC | 2902.0 | Value skewed after moving from COMP-2 to S9(7)V9(2) COMP |
| 2902.3 | Tue Feb 14 1995 10:39 | COMP-2 is not G-float with DEC COBOL | 6 lines |
TOPIC | 2903.0 | Display truncates after 80 characters |
| 2903.1 | Fri Feb 10 1995 09:59 | We'll need the source example | 11 lines |
TOPIC | 2904.0 | Fri Feb 10 1995 09:55 | DEC COBOL T2.2 sign-in | 6 lines |
| 2904.1 | Thu Mar 16 1995 09:06 | Which DEC COBOL compiler/RTL versions are in use? | 25 lines |
| 2904.2 | Thu Apr 20 1995 11:03 | See CLT::DEC_COBOL_IFT note 2.29 | 2 lines |
TOPIC | 2905.0 | Logical printing |
| 2905.1 | Tue Feb 14 1995 06:46 | What happens when you try to COPY to TTA0? | 47 lines |
TOPIC | 2907.0 | converting cobol/rms from vms to osf/1 |
| 2907.2 | Thu Feb 16 1995 10:46 | Input INDEXED files will need to be regenerated | 12 lines |
TOPIC | 2912.0 | VAX/COBL and DEC COBOL on OSF/1 |
| 2912.1 | Sat Feb 18 1995 06:42 | Summary from the release notes | 59 lines |
TOPIC | 2913.0 | Linker disliked cobol-e-namclass on axp |
| 2913.1 | Mon Feb 20 1995 09:48 | We would need to see the source file | 1 lines |
| 2913.5 | Tue Feb 21 1995 07:13 | I can not reproduce the linker problem you are seeing | 45 lines |
| 2913.7 | Tue Feb 21 1995 11:58 | V2.2 ship info | 19 lines |
| 2913.11 | Wed Feb 22 1995 08:25 | Do you still have a COBOL module which will not link? | 4 lines |
| 2913.14 | Thu Feb 23 1995 06:23 | We don't need COPY files and CDD definitions | 9 lines |
| 2913.15 | Wed Mar 08 1995 07:51 | No -E- errors during compilation | 2018 lines |
| 2913.16 | Thu Mar 09 1995 18:21 | Still can't reproduce the problem | 36 lines |
| 2913.17 | Thu Mar 09 1995 18:26 | LINK on Alpha works fine for me with -E- BADDTYPE | 35 lines |
| 2913.18 | Mon Mar 13 1995 06:51 | Attempt to link with PF587 | 27 lines |
| 2913.19 | Fri Mar 17 1995 14:52 | CDD record used in .17 | 21 lines |
| 2913.21 | Mon Apr 03 1995 09:33 | When the customer has the .COM, we will try it. | 3 lines |
| 2913.25 | Thu Apr 13 1995 07:43 | Problem reproduced | 70 lines |
| 2913.26 | Thu Apr 13 1995 12:43 | Fixed with V2.2-674 | 2 lines |
TOPIC | 2920.0 | syntax error,accvio and no .lis (2.1) |
| 2920.2 | Sun Jul 23 1995 15:20 | Fixed with T2.3-699 | 11 lines |
TOPIC | 2923.0 | RMS Key Qualifiers |
| 2923.3 | Fri Mar 10 1995 10:46 | Please post .COB and .FDL | 7 lines |
TOPIC | 2924.0 | COBOL standard problem |
| 2924.1 | Fri Mar 10 1995 07:33 | You need VAX COBOL V5.0 User Manual Appendix D | 37 lines |
TOPIC | 2925.0 | Does DEC COBOL work on OSF/1 V3.2? |
| 2925.3 | Tue Mar 14 1995 10:57 | All they need is the new compiler driver | 9 lines |
TOPIC | 2926.0 | Source produces large executable |
| 2926.1 | Tue Mar 14 1995 07:02 | See CLT::DEC_COBOL_IFT note 413 | 0 lines |
TOPIC | 2927.0 | READ causing memory leak on AXP? |
| 2927.1 | Wed Mar 15 1995 20:15 | See note 2868 | 0 lines |
TOPIC | 2929.0 | Problem with debugger in AXP 6.1 |
| 2929.5 | Thu Mar 16 1995 16:34 | Send mail to the Product Manager (SDTPMM::LEBLANC) | 11 lines |
| 2929.7 | Tue May 02 1995 07:54 | Debug-related PERFORM and CALL work | 11 lines |
| 2929.8 | Fri May 19 1995 18:16 | Fixed with T2.3-676 | 12 lines |
TOPIC | 2932.0 | accept with conversion consumes mem |
| 2932.10 | Tue May 02 1995 12:30 | No fix yet | 14 lines |
| 2932.12 | Mon May 15 1995 07:22 | Fixed with COBRTL.EXE T5.3-009 | 5 lines |
TOPIC | 2933.0 | COBOL Concise Reference Book |
| 2933.1 | Wed Mar 22 1995 06:20 | VAX COBOL Quick Reference Guide | 18 lines |
| 2933.3 | Thu Sep 14 1995 07:56 | Location for online version of V4.3 QRG | 6 lines |
TOPIC | 2934.0 | AXP DEC COBOL document |
| 2934.1 | Thu Mar 23 1995 06:15 | See CLT::DEC_COBOL_IFT | 8 lines |
TOPIC | 2935.0 | Sort problem in DECCobol v2.0 |
| 2935.1 | Thu Mar 23 1995 07:03 | First upgrade to DEC COBOL V2.1 or higher | 15 lines |
TOPIC | 2936.0 | How COBOL variables stored on file |
| 2936.3 | Fri Mar 24 1995 10:08 | Details in DEC/VAX COBOL Reference Manuals | 4 lines |
TOPIC | 2937.0 | Problem with COPY & DEC COBOL 2.1 |
| 2937.1 | Mon Mar 27 1995 17:13 | Status on testing of possible fix | 34 lines |
| 2937.2 | Mon Apr 03 1995 07:52 | Fixed with T2.2-664 | 38 lines |
TOPIC | 2941.0 | Warning while linking.. Suggestions |
| 2941.1 | Mon Mar 27 1995 06:50 | Try CSC32::COBOL2 | 10 lines |
TOPIC | 2942.0 | Exit Handler to run when A Program Exits --- Problem |
| 2942.1 | Mon Mar 27 1995 15:20 | You need the latest DEC COBOL RTL | 13 lines |
TOPIC | 2943.0 | Move COMP-2 to 999 : Input not equal Output |
| 2943.1 | Tue Mar 28 1995 06:58 | See note 2902 | 0 lines |
TOPIC | 2944.0 | cobol-dbms license - why do we need it? |
| 2944.4 | Tue May 02 1995 22:33 | Get COBOL and COBOL-DBMS PAKs from Digital | 8 lines |
| 2944.6 | Wed May 03 1995 11:52 | DML = Data Manipulation Language | 11 lines |
TOPIC | 2946.0 | DIVBYZER when /NOOPTIMIZE ??? |
| 2946.1 | Wed Mar 29 1995 14:03 | Fixed with V2.1-622 | 24 lines |
TOPIC | 2947.0 | NAMCLASS error while copying from CDD |
| 2947.1 | Thu Mar 30 1995 19:01 | See 2913.12 for another NAMCLASS situation | 0 lines |
| 2947.3 | Fri Mar 31 1995 08:24 | Post /LIST/COPY_LIST page with NAMCLASS diag | 3 lines |
| 2947.6 | Tue Dec 17 1996 06:08 | See 2913.26 | 17 lines |
TOPIC | 2949.0 | vax cobol to dec cobol migration problems |
| 2949.1 | Mon Apr 03 1995 09:24 | Which version of DEC COBOL is in use? | 32 lines |
TOPIC | 2953.0 | AXP : DISPLAY with video attribut problem |
| 2953.1 | Fri Apr 14 1995 13:33 | See CLT::DEC_COBOL_IFT 423,424,425 | 0 lines |
TOPIC | 2955.0 | C-ISAM File manager access through OSF/1 |
| 2955.1 | Wed Apr 19 1995 09:23 | You must get a kit/license from Informix - see the RBI | 3 lines |
TOPIC | 2956.0 | fixed commands starting in column 6.... |
| 2956.1 | Wed Apr 19 1995 09:26 | COBOL source file needed | 3 lines |
| 2956.4 | Tue May 02 1995 08:19 | Could not reproduce with VAX COBOL V5.2 | 522 lines |
| 2956.5 | Wed May 03 1995 06:59 | I could not duplicate the problem with VAX COBOL V4.4 | 34 lines |
| 2956.11 | Tue May 16 1995 10:57 | Problem is probably in SCA | 23 lines |
| 2956.12 | Fri Jun 02 1995 09:11 | See TURRIS::SOURCE_CODE_ANALYZER note 814 | 31 lines |
TOPIC | 2958.0 | VAX COBOL to MFCOBOL CONVERSION HELP ?? |
| 2958.1 | Wed Apr 26 1995 07:05 | One solution is REFORMAT | 8 lines |
TOPIC | 2959.0 | LINKING ERROR IN DEC COBOL |
| 2959.1 | Tue May 02 1995 07:44 | DFARTL must be installed | 15 lines |
TOPIC | 2961.0 | Sun May 14 1995 12:46 | COBOL DECUS presentations | 27 lines |
| 2961.1 | Sun May 25 1997 13:59 | DEC COBOL V2.4 for Windows NT Alpha | 10 lines |
TOPIC | 2962.0 | Report Writer ignores scaling in control break field |
| 2962.1 | Tue May 16 1995 07:58 | Source example needed | 4 lines |
| 2962.3 | Wed May 24 1995 09:40 | Invalid decimal data | 27 lines |
| 2962.5 | Wed May 31 1995 07:50 | Fixed with DEC COBOL T2.3-681 | 6 lines |
| 2962.7 | Thu Jun 01 1995 07:58 | V2.3 is the next planned DEC COBOL bug fix release | 5 lines |
TOPIC | 2963.0 | Wed May 24 1995 07:51 | Announcing VAX COBOL V5.3 | 54 lines |
| 2963.1 | Wed May 24 1995 08:01 | 2 outstanding problems with VAX COBOL T5.3 FT1 | 9 lines |
| 2963.2 | Fri May 26 1995 15:48 | VAX COBOL T5.3 FT1 notes (ftp.digital.com) | 57 lines |
| 2963.3 | Wed Jul 26 1995 13:56 | VAX COBOL V5.3 | 66 lines |
| 2963.4 | Wed Jul 26 1995 19:51 | VAX COBOL V5.3 (ftp.digital.com) | 56 lines |
| 2963.6 | Fri Jul 28 1995 12:32 | My KITINSTAL.COM has V5.3-011 | 9 lines |
| 2963.7 | Fri Jul 28 1995 12:57 | We'll add the check for V5.1-008 | 1 lines |
| 2963.13 | Fri Jul 28 1995 17:40 | VAX COBOL V5.3 - corrected kit | 71 lines |
| 2963.14 | Tue Aug 01 1995 16:53 | VAX COBOL V5.3 - RBI and SPD now available | 74 lines |
| 2963.15 | Thu Aug 03 1995 18:47 | VAX COBOL V5.3 (ftp.digital.com) | 62 lines |
| 2963.16 | Thu Aug 03 1995 18:52 | Procedure to update T5.3-009 COBRTL.EXE | 10 lines |
| 2963.17 | Mon Aug 07 1995 16:40 | VAX COBOL V5.3 - RBI location corrected | 75 lines |
| 2963.22 | Tue Aug 29 1995 15:08 | John's description in .19 is the best thing to tell customers | 19 lines |
| 2963.29 | Tue Oct 03 1995 14:50 | COBRTL.EXE V5.3-012 now available | 23 lines |
| 2963.31 | Thu Oct 26 1995 13:02 | Next week at the earliest | 2 lines |
| 2963.32 | Mon Dec 04 1995 15:32 | The VAX COBOL RTL V5.3 ECO kit is COBRTLVAXE01053 | 8 lines |
| 2963.33 | Sun Dec 17 1995 07:04 | VAX COBOL V5.3-41 with RMS special registers fix | 23 lines |
| 2963.35 | Tue Jan 02 1996 13:43 | VAX COBOL V5.3-42 / VAX COBOL RTL V5.3-012 | 20 lines |
TOPIC | 2964.0 | Converting RM COBOL 85 |
| 2964.1 | Wed May 24 1995 15:02 | Also try MEMIT::CONVERSION | 14 lines |
TOPIC | 2966.0 | %COB-E-DIVBY_ZER, divide by zero; Execution continues |
| 2966.1 | Tue May 30 1995 07:22 | We need a source example if the failure occurs with V5.2 | 33 lines |
TOPIC | 2967.0 | variable length record range not specified got empty file. |
| 2967.1 | Thu Jun 01 1995 07:55 | We need to see the source example which shows the problem | 0 lines |
| 2967.3 | Thu Jun 22 1995 08:21 | Do these problems occur /NOOPT? with V2.2? | 23 lines |
TOPIC | 2968.0 | Cobol 5.1 ACCVIO with 5.0 or lower no problem |
| 2968.1 | Thu Jun 01 1995 08:09 | Fixed with VAX COBOL V5.2=35 | 31 lines |
TOPIC | 2971.0 | Migration Filters? |
| 2971.1 | Thu Jun 15 1995 19:11 | VAX COBOL has /STANDARD=OPENVMS_AXP | 28 lines |
TOPIC | 2972.0 | formfeed problems on parallel printer on cobol pgm |
| 2972.1 | Fri Jun 16 1995 08:10 | Upgrade to V2.2-674 and latest RTL; see note 2767 | 19 lines |
TOPIC | 2973.0 | Looking for DEC COBOL Expertise |
| 2973.1 | Tue Jun 20 1995 12:04 | IBM conversion issues | 22 lines |
TOPIC | 2976.0 | CANCEL causes ACCVIO with EXTERNAL statment. |
| 2976.1 | Mon Jul 03 1995 11:24 | Fixed with V2.2-674 | 11 lines |
| 2976.4 | Wed Jul 05 1995 06:50 | V2.2-674 /NATIONALITY=JAPAN should work fine for you | 7 lines |
TOPIC | 2977.0 | V5.0 and VMS6.1 and kit location questions |
| 2977.1 | Thu Jul 06 1995 12:48 | You need to get VAX COBOL V5.2 from the SSB | 9 lines |
TOPIC | 2978.0 | problem on alpha axp and if |
| 2978.1 | Thu Jul 06 1995 12:55 | Use /CHECK=DECIMAL - see 2823.1 | 0 lines |
| 2978.4 | Fri Jul 07 1995 07:32 | Invalid runtime dec data cannot always be flagged during compile | 14 lines |
TOPIC | 2983.0 | record locking on indexed file |
| 2983.3 | Sun Jul 23 1995 21:27 | OpenVMS VAX X6.3? | 4 lines |
| 2983.6 | Wed Jul 26 1995 14:00 | Try suggestions in .2 and VAX COBOL V5.3 | 5 lines |
TOPIC | 2985.0 | %SYSTEM-F-ACCVIO on COBOL V2.1-543 |
| 2985.1 | Tue Jul 25 1995 08:09 | Several compile ACCVIOs with V2.1 are fixed in V2.2 | 26 lines |
TOPIC | 2986.0 | COBOL program generate strange DECnet packet |
| 2986.1 | Thu Jul 27 1995 08:05 | Does CALL "LIB$PUT_OUTPUT" work OK? | 9 lines |
| 2986.4 | Fri Jul 28 1995 07:37 | LIB$GET_INPUT | 5 lines |
| 2986.6 | Tue Aug 01 1995 06:57 | DISPLAY mostly intended for terminal screen output | 4 lines |
TOPIC | 2987.0 | Application problem. |
| 2987.1 | Mon Aug 07 1995 14:56 | Upgrade to latest DEC$COBRTL.EXE and DEC COBOL V2.2 | 9 lines |
TOPIC | 2989.0 | Sequential file read optimisation |
| 2989.1 | Mon Aug 14 1995 07:46 | Which version of VAX COBOL are you using? | 19 lines |
TOPIC | 2990.0 | VAX7720 2 times slower than VAX6530. |
| 2990.1 | Tue Aug 22 1995 07:59 | Questions | 26 lines |
TOPIC | 2993.0 | How to find out number of arguments during runtime? |
| 2993.1 | Thu Aug 24 1995 10:13 | FUNCTION ARGCOUNT in DEC/VAX COBOL on OpenVMS | 8 lines |
TOPIC | 2994.0 | SET COMP-3-field versus MOVE TO COMP-3-field |
| 2994.1 | Fri Aug 25 1995 08:51 | Use signed COMP-3 | 13 lines |
TOPIC | 2995.0 | error in linking |
| 2995.1 | Wed Aug 30 1995 08:11 | Which object modules does your LINK/MAP/FULL show? | 43 lines |
TOPIC | 2996.0 | Problem link on AXP |
| 2996.2 | Thu Aug 31 1995 15:05 | You need DEC$COBRTL.EXE later than V2.0 | 6 lines |
TOPIC | 2997.0 | result is different on each other(vax, axp) |
| 2997.1 | Fri Sep 01 1995 07:38 | Numeric comparison with invalid decimal data | 14 lines |
TOPIC | 2999.0 | Comp 1 -> FFloat |
| 2999.2 | Thu Sep 07 1995 14:49 | Don't use /FLOAT=IEEE_FLOAT | 2 lines |
TOPIC | 3000.0 | Axp calculate wrong problem |
| 3000.1 | Tue Sep 12 1995 07:47 | Fixed with T2.3-739 | 28 lines |
TOPIC | 3001.0 | AXP Compiler performance poor ? |
| 3001.1 | Thu Sep 14 1995 09:42 | Upgrade to DEC COBOL V2.2 | 7 lines |
TOPIC | 3003.0 | Read (EOF) V5.0 and V5.1 (and above) |
| 3003.1 | Fri Sep 22 1995 18:58 | No next valid record bugs corrected with V5.1 | 17 lines |
| 3003.3 | Sat Oct 07 1995 08:35 | Here is the Stars article | 62 lines |
TOPIC | 3006.0 | -F-DECINV, decimal invalid operand Problem on AXP |
| 3006.1 | Mon Oct 09 1995 07:46 | We need the COPY libraries | 25 lines |
| 3006.2 | Tue Oct 10 1995 14:52 | See DEC_COBOL_IFT note 490 and COBOL note 3000.1 | 9 lines |
TOPIC | 3007.0 | 5.3 & CMA$TIS_SHR |
| 3007.1 | Tue Oct 10 1995 12:13 | Restriction removed with COBRTL.EXE V5.3-012 - see 2963.29 | 35 lines |
TOPIC | 3008.0 | ACCVIO on Compile, VA=00000058, PC=002A91c4 |
| 3008.1 | Fri Oct 20 1995 08:20 | Several V2.2 compile ACCVIOs fixed with T2.3 | 33 lines |
| 3008.4 | Tue Oct 24 1995 06:31 | DEC COBOL V2.3 release schedule | 13 lines |
| 3008.7 | Tue Oct 31 1995 06:42 | See CLT::DEC_COBOL_IFT 447.10 | 32 lines |
TOPIC | 3009.0 | why does image generated from Cobol program exit ALL-IN-1? |
| 3009.1 | Mon Oct 23 1995 09:50 | Check return status from system services | 21 lines |
TOPIC | 3010.0 | AXP Cobol and DBMS gives UnDefSym |
| 3010.1 | Tue Oct 24 1995 14:43 | Fixed with DEC COBOL T2.3-723 FT1 | 9 lines |
| 3010.3 | Thu Oct 26 1995 13:06 | Does the problem occur with COBOL/RESERVED_WORDS=XOPEN? | 10 lines |
| 3010.5 | Thu Nov 02 1995 06:28 | /RESERVED_WORDS=NOXOPEN problem fixed with T2.3-723 | 8 lines |
TOPIC | 3011.0 | v3.4 TO v5.2 incompatibility |
| 3011.1 | Tue Oct 31 1995 07:25 | I could not reproduce the reported V3.4 / V5.2 difference | 66 lines |
| 3011.3 | Thu Nov 02 1995 05:31 | VAX COBOL V5.3 is the current supported version of VAX COBOL | 9 lines |
TOPIC | 3012.0 | Moving from V4 to V5 |
| 3012.1 | Wed Nov 01 1995 06:16 | V5.1-10 - CDD/R INITIAL_VALUE IS | 10 lines |
| 3012.5 | Sun Nov 19 1995 06:21 | Contact the DEC/VAX COBOL product manager | 8 lines |
TOPIC | 3013.0 | COBOL and CDDSHR |
| 3013.1 | Fri Nov 03 1995 16:37 | I agree - there are better ways today to implement this support | 11 lines |
TOPIC | 3014.0 | COBOL I/O performance w OPEN OUTPUT ALLOWING READERS |
| 3014.4 | Tue Nov 07 1995 21:32 | Cathy Axel is in California this week | 5 lines |
| 3014.7 | Wed Nov 08 1995 10:17 | Which version of RMS does NOT support shared seq writes? | 21 lines |
| 3014.11 | Wed Nov 08 1995 18:36 | APPLY DEFERRED-WRITE for ORG SEQ (OpenVMS Alpha) - T2.3-784 | 27 lines |
| 3014.16 | Tue Jan 02 1996 07:26 | APPLY DEFERRED-WRITE for ORG SEQ (OpenVMS VAX) - V5.3-42 | 27 lines |
TOPIC | 3015.0 | Cobol V5.3 ACCVIO VA=0000018A,PC=000205DC |
| 3015.1 | Wed Nov 08 1995 15:10 | RECACTUSE | 28 lines |
| 3015.6 | Thu Nov 09 1995 06:29 | I could not reproduce the ACCVIO you are seeing | 36 lines |
| 3015.7 | Thu Nov 09 1995 06:33 | For me, DEC COBOL T2.3 and VAX COBOL V5.3 give RECACTUSE | 4 lines |
| 3015.12 | Fri Nov 17 1995 09:29 | We need your version of the source which does NOT get RECACTUSE | 7 lines |
| 3015.15 | Fri Nov 17 1995 14:09 | I duplicated the ACCVIO you are seeing | 5 lines |
| 3015.18 | Mon Nov 27 1995 13:00 | No fix yet | 10 lines |
| 3015.20 | Sun Dec 17 1995 07:06 | Fixed with VAX COBOL V5.3-41 - see 2963.33 | 0 lines |
| 3015.22 | Thu Dec 21 1995 10:58 | That compiler image requires RDBSHR | 9 lines |
TOPIC | 3016.0 | COPY from CDD fails on Alpha |
| 3016.1 | Sat Nov 11 1995 06:07 | Upgrade to DEC COBOL V2.2 | 7 lines |
TOPIC | 3017.0 | %COBOL-F-UNDEFSYM Error |
| 3017.1 | Tue Nov 14 1995 11:29 | Use ASSIGN TO "S-YS010" | 12 lines |
| 3017.3 | Sat Mar 23 1996 06:44 | Fixed with V2.3-793 | 2 lines |
TOPIC | 3018.0 | Assertion Failure (Fetch first & Erase all not compatible ?) |
| 3018.1 | Wed Nov 15 1995 05:46 | Could you try T2.3-784? | 29 lines |
| 3018.6 | Fri Nov 24 1995 09:52 | FETCH FIRST WITHIN/USING followed by ERASE ALL | 21 lines |
| 3018.7 | Sat Nov 25 1995 09:44 | Fixed with 2.3-790 | 4 lines |
| 3018.9 | Mon Nov 27 1995 06:15 | 2.3-790 compiler available | 11 lines |
TOPIC | 3021.0 | A format error |
| 3021.1 | Wed Nov 15 1995 16:29 | Try COBOL/ANSI and COBOL/NOANSI | 16 lines |
TOPIC | 3023.0 | compile accvio PC=003010BC |
| 3023.1 | Wed Nov 22 1995 10:41 | Could you try T2.3-784 | 7 lines |
| 3023.3 | Thu Nov 23 1995 15:43 | G_FLOAT is in the T2.3 .CLD | 17 lines |
| 3023.8 | Thu Nov 30 1995 10:51 | /STA=V3/OPT | 13 lines |
| 3023.10 | Mon Dec 11 1995 09:44 | Probably not until next month at the earliest | 6 lines |
| 3023.11 | Sat Mar 23 1996 06:36 | Continue to use temporary workaround - compile /NOOPT | 13 lines |
| 3023.12 | Sat May 25 1996 08:48 | Fixed with DEC COBOL V2.4 | 10 lines |
TOPIC | 3024.0 | ACCVIO on OPEN VAX COBOL V5.3-40 - code generation bug? |
| 3024.2 | Sun Nov 26 1995 23:32 | Probable duplicate of CLT::COBOL 3015 | 3 lines |
| 3024.5 | Sun Dec 17 1995 07:08 | Fixed with VAX COBOL V5.3-41 - see 2963.33 | 0 lines |
TOPIC | 3025.0 | %COB-F-WRITE_SIZE varying record size on AXP |
| 3025.3 | Tue Dec 05 1995 09:13 | What happens when you compile /NOOPT/CHECK/WARNINGS=ALL? | 85 lines |
TOPIC | 3026.0 | %GEM-F-ASSERTION, Compiler internal error |
| 3026.1 | Wed Dec 06 1995 05:40 | Try the V2.3-793 compiler | 3 lines |
TOPIC | 3027.0 | COBOL-W-ALL_LOST, All digits lost in numeric move |
| 3027.3 | Thu Dec 07 1995 07:04 | Reference is in the DEC COBOL User Manual | 41 lines |
| 3027.6 | Fri Dec 22 1995 22:19 | Fixed with V2.3-795 - see CLT::DEC_COBOL_IFT note 2.42 | 0 lines |
| 3027.7 | Wed Jan 03 1996 06:52 | V2.3-795 kit available - see CLT::DEC_COBOL_IFT note 2.43 | 0 lines |
TOPIC | 3030.0 | New problem with RMS-FILENAME with 5.3? |
| 3030.1 | Fri Dec 08 1995 05:19 | See notes 3015,3024 | 4 lines |
| 3030.5 | Tue Dec 12 1995 05:17 | Problem unrelated to declaratives | 5 lines |
| 3030.7 | Sun Dec 17 1995 07:09 | Fixed with VAX COBOL V5.3-41 - see 2963.33 | 0 lines |
TOPIC | 3032.0 | why works differtly on AXP/OVMS ? |
| 3032.1 | Wed Dec 13 1995 11:13 | Fixed with DEC COBOL V2.3 | 9 lines |
TOPIC | 3034.0 | 2 versions on same CD |
| 3034.1 | Thu Dec 14 1995 14:01 | VAX COBOL/Japanese uses the older version of VAX COBOL on the CD | 18 lines |
TOPIC | 3035.0 | cobol V2.3 Rel. notes clarifications.. |
| 3035.1 | Fri Dec 15 1995 10:49 | See note 3000 and CLT::DEC_COBOL_IFT notes 486,494 | 32 lines |
| 3035.3 | Fri Feb 09 1996 08:14 | RE: .2 - fixed with V2.3-795 | 9 lines |
TOPIC | 3037.0 | 64 bit support for OpenVMS??? |
| 3037.3 | Wed Jan 10 1996 10:49 | USAGE IS POINTER supports 64-bit addresses only on Digital UNIX | 12 lines |
TOPIC | 3040.0 | %COBRTLVAXE01-I-IDNTCK when installing COBRTLVAXE01053. |
| 3040.4 | Tue Mar 19 1996 07:20 | Fixed with VAX COBOL V5.4 | 1 lines |
TOPIC | 3041.0 | READ INTO without AT END and INVALID KEY |
| 3041.1 | Tue Jan 16 1996 22:52 | Which version of VAX COBOL? /STANDARD=85? | 9 lines |
| 3041.4 | Wed Feb 14 1996 06:44 | Problem duplicated on our system | 9 lines |
| 3041.5 | Mon Feb 19 1996 13:30 | Fixed with V2.3-807 | 12 lines |
TOPIC | 3042.0 | Shared sequential output file misses records |
| 3042.1 | Wed Jan 17 1996 06:36 | See CLT::DEC_COBOL_IFT notes 508 and 509 | 17 lines |
TOPIC | 3043.0 | S9(4) COMP - IBM Migration |
| 3043.1 | Wed Jan 17 1996 09:08 | Yes. DEC/VAX COBOL have 2-byte S9(4) COMP. | 24 lines |
TOPIC | 3044.0 | SHRIDMISMAT on customer's program after VMS and CObol upgrade |
| 3044.1 | Thu Jan 18 1996 06:27 | Which shareable images is D_HANDLER linked against? | 18 lines |
TOPIC | 3045.0 | ACCVIO when compiled with /Float=IEEE on axp |
| 3045.1 | Fri Jan 19 1996 08:00 | MTH$SQRT does not support /FLOAT=IEEE | 47 lines |
TOPIC | 3046.0 | Compile ACCVIO with v2.3 using Function Char on AXP VMS |
| 3046.1 | Tue Jan 23 1996 06:57 | Another temporary workaround - compile /NOOPT | 21 lines |
| 3046.3 | Fri Mar 22 1996 18:08 | Fixed with DEC COBOL V2.3-827 | 5 lines |
TOPIC | 3048.0 | ACCVIO on Compile |
| 3048.1 | Wed Jan 31 1996 00:05 | Try DEC COBOL V2.3 | 54 lines |
TOPIC | 3049.0 | FIND FIRST Statement Question (BUGCHECK) |
| 3049.1 | Wed Jan 31 1996 00:15 | Try DEC COBOL V2.3 | 11 lines |
TOPIC | 3050.0 | OpenVMS V7.0 support ? |
| 3050.1 | Thu Feb 01 1996 08:50 | VAX COBOL V5.3 / DEC COBOL V2.3 are supported on OpenVMS V7.0 | 28 lines |
TOPIC | 3051.0 | Mon Feb 05 1996 16:24 | Compuserve and ftp problems | 105 lines |
TOPIC | 3053.0 | Source debugging with CDD DICTIONARY |
| 3053.1 | Wed Feb 07 1996 06:21 | Use DBG> EXAMINE EMPLOYEE-ID | 37 lines |
| 3053.2 | Fri Apr 05 1996 15:34 | -_ problem fixed in Gryphon release of OpenVMS Alpha DEBUG | 19 lines |
| 3053.3 | Wed Aug 21 1996 09:22 | DEBUG kit available for underscore problem | 119 lines |
TOPIC | 3054.0 | COMP field seem to give invalid results |
| 3054.1 | Thu Feb 08 1996 08:07 | Try DEC COBOL V2.3 | 34 lines |
TOPIC | 3055.0 | Spawn with access violation |
| 3055.1 | Fri Feb 09 1996 06:42 | Your LIB$SPAWN calls needs 2 OMITTED arguments | 46 lines |
TOPIC | 3056.0 | Is it possible to write COBOL programs with varable number of input parameters??... |
| 3056.1 | Fri Feb 09 1996 06:11 | FUNCTION ARGCOUNT | 9 lines |
TOPIC | 3058.0 | COBOL Postscript DOCs needed |
| 3058.1 | Mon Feb 12 1996 14:15 | See CLT::DEC_COBOL_IFT note 2.38 | 17 lines |
TOPIC | 3059.0 | Calling C++ routines from Microfocus Cobol |
| 3059.2 | Wed Feb 14 1996 08:47 | Note that this is cross-posted in CSC32::COBOL2 note 498 | 11 lines |
TOPIC | 3060.0 | Problem on Unix reading text files |
| 3060.1 | Fri Feb 16 1996 08:30 | LINE SEQUENTIAL? | 11 lines |
TOPIC | 3062.0 | How to use symbol with lib$spawn |
| 3062.1 | Wed Mar 06 1996 08:02 | Try new X/Open logical names support | 26 lines |
TOPIC | 3064.0 | Source line more than 132... |
| 3064.1 | Wed Mar 13 1996 06:05 | VAX COBOL /LIS has 118 characters max for any source line | 39 lines |
TOPIC | 3065.0 | Loop detection tools ? |
| 3065.3 | Thu Mar 14 1996 07:03 | Known problem with overflow detection | 11 lines |
TOPIC | 3066.0 | Is there an ANSI 89 ?? |
| 3066.1 | Wed Mar 13 1996 13:24 | -89 standards addendum added functions with 4-char years | 20 lines |
TOPIC | 3067.0 | Problem with COBOL calling DECForms |
| 3067.1 | Fri Mar 15 1996 14:33 | The customer should be running DEC COBOL V2.3 | 66 lines |
| 3067.5 | Mon Mar 18 1996 13:49 | 38 V2.2 bugs fixed in V2.3 | 12 lines |
TOPIC | 3069.0 | Changing from VAX to Alpha gives problems |
| 3069.1 | Mon Mar 18 1996 13:45 | Upgrade to V2.3; complete source examples needed | 7 lines |
TOPIC | 3070.0 | EBCDIC to ASCII with packed decimal |
| 3070.1 | Wed Mar 20 1996 10:11 | How is this packed format different from VAX/Alpha? | 21 lines |
TOPIC | 3072.0 | EXIT does not terminate PERFORM |
| 3072.6 | Tue Mar 26 1996 13:03 | Correct. | 1 lines |
TOPIC | 3073.0 | ACCEPT inp_var FROM DATE futures |
| 3073.1 | Tue Mar 26 1996 07:47 | See CLT::DEC_COBOL_IFT note 488.3 for more details | 43 lines |
TOPIC | 3074.0 | File At End (sts 13) ignored |
| 3074.1 | Thu Mar 28 1996 07:04 | Customer should install DEC COBOL V2.3 | 9 lines |
TOPIC | 3075.0 | Again COMPUTE ROUNDED && COBOL 2.3 |
| 3075.1 | Tue Apr 02 1996 07:30 | Documented difference between VAX COBOL and DEC COBOL | 162 lines |
| 3075.3 | Wed Apr 03 1996 07:08 | Use /WARNINGS=ALL with DEC COBOL V2.3-831 or higher | 52 lines |
| 3075.6 | Wed Apr 03 1996 13:16 | Break divide operations out of the COMPUTEs | 10 lines |
| 3075.7 | Wed Apr 03 1996 13:28 | Intermediate precision examples | 37 lines |
| 3075.9 | Tue Apr 09 1996 12:18 | ROUNDED impacts SIZE of intermediate results | 12 lines |
| 3075.11 | Tue Apr 22 1997 08:04 | CIT3 available for OpenVMS Alpha with 2.4-909 | 2 lines |
TOPIC | 3076.0 | DISPLAY (DEC COBOL) - Cursor positioning |
| 3076.1 | Wed Apr 03 1996 06:53 | You need to use ANSI ACCEPT/DISPLAY | 24 lines |
TOPIC | 3079.0 | Debugger problem with a DEC-COBOL program |
| 3079.1 | Thu Apr 11 1996 10:28 | Try DEC COBOL V2.3 | 45 lines |
| 3079.3 | Thu Apr 11 1996 13:21 | Also see note 3077 | 1 lines |
| 3079.4 | Thu Apr 11 1996 13:26 | Also see CLT::DEC_COBOL_IFT note 529 | 18 lines |
| 3079.5 | Thu Apr 11 1996 14:26 | DEC_COBOL_IFT 529 is probably a different problem | 9 lines |
TOPIC | 3080.0 | DEBUG issue resolved with DC V2.3? |
| 3080.1 | Fri Apr 12 1996 16:44 | Summary of DEC COBOL V2.3-831/-93 | 71 lines |
TOPIC | 3081.0 | MF COBOL->DEC COBOL issues. |
| 3081.1 | Mon Apr 15 1996 15:41 | Try SET TO REFERENCE | 61 lines |
TOPIC | 3082.0 | Sybase preprocessor support |
| 3082.1 | Tue Apr 16 1996 15:36 | See FUTURS::SYBASE note 368 | 28 lines |
TOPIC | 3083.0 | support for vt520 |
| 3083.1 | Wed Apr 17 1996 08:00 | Use existing VT1xx,VT2xx,VT3xx,VT4xx support | 5 lines |
TOPIC | 3084.0 | Accept at Line and Column of 8 bit characters |
| 3084.1 | Wed Apr 17 1996 11:36 | Problem duplicated on Digital UNIX V3.0 | 25 lines |
TOPIC | 3085.0 | ACCEPT when read from command procedure |
| 3085.1 | Thu Apr 18 1996 06:59 | Workaround in V2.3-83 DEC COBOL RTL | 8 lines |
TOPIC | 3086.0 | Gotchas with dowgrading COBOL to earlier version |
| 3086.1 | Thu Apr 18 1996 18:25 | We need the source example with the "low values" problem | 7 lines |
TOPIC | 3091.0 | DEC Cobol and underscores included in variablenames |
| 3091.1 | Thu May 02 1996 10:00 | See note 2839 | 0 lines |
TOPIC | 3092.0 | Bug in INSPECT !? |
| 3092.1 | Mon May 06 1996 09:03 | Problem duplicated; 1 other workaround identified | 35 lines |
| 3092.3 | Sun Jun 02 1996 20:53 | Fixed with VAX COBOL V5.3-43 compiler | 6 lines |
TOPIC | 3093.0 | Alpha SORT VARYING file pads all records to max length? |
| 3093.1 | Thu May 09 1996 19:45 | VARYING and SORT GIVING without DEPENDING ON | 74 lines |
| 3093.3 | Fri May 10 1996 07:52 | SORT USING file does not need DEPENDING ON | 6 lines |
| 3093.4 | Thu May 30 1996 07:24 | Fixed with T2.4-839 DEC COBOL compiler | 14 lines |
TOPIC | 3094.0 | Q on DC Compile Performance vs VC |
| 3094.1 | Sat May 11 1996 07:30 | Guidelines to improve compilation performance | 249 lines |
| 3094.2 | Mon May 13 1996 07:43 | One compilation performance data point | 38 lines |
TOPIC | 3095.0 | Spurious RECACTPER again in Alpha V5.2 and V5.3 |
| 3095.1 | Mon May 13 1996 00:41 | Does the customer get different results between DEC/VAX COBOL? | 59 lines |
| 3095.3 | Tue May 14 1996 08:10 | See note 2853.1 | 3 lines |
| 3095.5 | Mon Jun 17 1996 06:47 | No solution yet for /CHECK=PERFORM case | 6 lines |
| 3095.7 | Sun Jul 07 1996 11:22 | Fixed with T2.4-844 DEC COBOL compiler | 4 lines |
TOPIC | 3096.0 | G_FLOAT support on VAX ??? |
| 3096.1 | Tue May 14 1996 13:36 | Please send this request to DEC/VAX COBOL product management | 7 lines |
TOPIC | 3097.0 | COB-E-INVBUFSIZ |
| 3097.1 | Wed May 15 1996 12:54 | DEC COBOL does not issue INVBUFSIZ | 18 lines |
TOPIC | 3099.0 | accept with conversion behaviour |
| 3099.1 | Tue May 21 1996 08:07 | Expected behavior | 23 lines |
TOPIC | 3100.0 | ACCVIO at compile time |
| 3100.1 | Thu May 23 1996 07:05 | Upgrade to DEC COBOL V2.3 | 44 lines |
TOPIC | 3101.0 | performance optimization? |
| 3101.1 | Tue May 28 1996 15:49 | DEC COBOL uses the GEM backend | 13 lines |
TOPIC | 3102.0 | assertion failure from precompiler |
| 3102.1 | Tue May 28 1996 23:23 | Try ORAREP::NOMAHS::SQL | 24 lines |
TOPIC | 3103.0 | DIFFERENT I/O STATUS CODE ON VAX AND ALPHA - WHY? |
| 3103.1 | Wed May 29 1996 07:16 | Try DEC COBOL V2.3; try /NOOPT/CHECK/WARN=ALL with DEC COBOL | 47 lines |
TOPIC | 3104.0 | Incorrect alphanumeric truncation |
| 3104.2 | Fri May 31 1996 13:22 | Dan will be looking at this program | 3 lines |
| 3104.5 | Mon Jun 03 1996 14:58 | Fixed with V2.3-840 DEC COBOL compiler | 8 lines |
| 3104.6 | Sun Jun 09 1996 19:41 | Fixed with V2.3-840 DEC COBOL compiler | 42 lines |
TOPIC | 3105.0 | Problems with LIB$FIND_IMAGE_SYMBOL on ALPHA |
| 3105.1 | Fri May 31 1996 13:31 | INV$_VERSION defined in both shared images? | 13 lines |
| 3105.3 | Fri May 31 1996 15:19 | Symbol Vectors | 25 lines |
TOPIC | 3106.0 | Dynamic linking/loading on OSF |
| 3106.1 | Tue Jun 04 1996 10:09 | DEC COBOL implements CALL <variable> using nlist() on Digital UNIX | 6 lines |
TOPIC | 3108.0 | Search All fails to find all entries |
| 3108.2 | Wed Jun 05 1996 15:33 | Use unsigned DISPLAY numeric | 25 lines |
| 3108.3 | Mon Jun 10 1996 17:31 | SEARCH ALL fails because array is not in order | 106 lines |
TOPIC | 3109.0 | Fri Jun 07 1996 09:41 | COBOL survey on the World Wide Web | 35 lines |
TOPIC | 3110.0 | Pointer for COBOL V2.1 User Guide ? |
| 3110.1 | Fri Jun 14 1996 09:36 | See CLT::DEC_COBOL_IFT note 2.47 for V2.3 docs | 14 lines |
TOPIC | 3113.0 | COBOL on UNIX TAPE access problem |
| 3113.2 | Thu Jun 20 1996 08:51 | Also see CLT::DEC_COBOL_IFT note 526 | 44 lines |
TOPIC | 3117.0 | COB$CALL on Alpha ? |
| 3117.1 | Mon Jul 01 1996 06:33 | With DEC COBOL try cobfunc, cobcall, cobcancel | 6 lines |
TOPIC | 3118.0 | modifying alternate key caused read problem in COBOL |
| 3118.1 | Thu Jul 04 1996 07:48 | Try VAX COBOL V5.3 | 33 lines |
TOPIC | 3119.0 | Two COBOL-Ingres-UNIX questions--who can help? |
| 3119.1 | Wed Jul 10 1996 10:35 | Which Digital COBOL is in use by the customer | 4 lines |
TOPIC | 3121.0 | help with setting environment variables on Digital UNIX |
| 3121.1 | Fri Jul 12 1996 11:27 | Explanation of environment variable scope from Craig | 22 lines |
| 3121.3 | Fri Jul 12 1996 12:38 | Added to the list of needed documentation updates | 24 lines |
| 3121.4 | Sat Jul 13 1996 10:20 | Micro Focus COBOL/2 gives the same results | 2 lines |
TOPIC | 3122.0 | file handling exhausts swap memory on unix 3.2c |
| 3122.1 | Wed Jul 17 1996 10:49 | See CLT::DEC_COBOL_IFT note 520 | 13 lines |
TOPIC | 3123.0 | Migration to DEC-COBOL/UNIX questions? |
| 3123.1 | Wed Jul 17 1996 11:12 | See CLT::DEC_COBOL_IFT note 2.47 for pointers to V2.3 docs | 88 lines |
| 3123.3 | Wed Jul 17 1996 12:51 | See CLT::DEC_COBOL_IFT note 2.47 | 6 lines |
| 3123.5 | Thu Jul 18 1996 07:59 | Use non-hyphen name as the program id | 3 lines |
| 3123.7 | Thu Jul 18 1996 08:05 | Also look at -names | 5 lines |
| 3123.8 | Thu Jul 18 1996 08:14 | Max filename length for ORGANIZATION INDEXED | 16 lines |
| 3123.10 | Thu Jul 18 1996 08:44 | See CLT::DEC_COBOL_IFT note 538 | 4 lines |
| 3123.11 | Thu Jul 18 1996 09:18 | Calling C from COBOL using "_" in names | 32 lines |
TOPIC | 3124.0 | indexed files need write access to .idx open for read. |
| 3124.1 | Fri Jul 19 1996 12:16 | C-ISAM ISAM and .idx rw-r--r-- | 9 lines |
TOPIC | 3126.0 | Can't print the Cobol manuals |
| 3126.2 | Tue Jul 23 1996 17:10 | See CLT::DEC_COBOL_IFT note 2.38 | 0 lines |
| 3126.3 | Mon Jul 29 1996 19:14 | Problem resolved | 25 lines |
TOPIC | 3128.0 | Errors with /OPTIMIZE |
| 3128.1 | Fri Jul 26 1996 07:44 | Try the DEC COBOL T2.4-853 compiler | 10 lines |
| 3128.3 | Mon Jul 29 1996 15:01 | Please ask the customer to reconsider trying T2.4-853 FT1 | 10 lines |
TOPIC | 3129.0 | standard=v3 and 5.3 vax cobol |
| 3129.1 | Tue Jul 30 1996 11:35 | Try COBOLVAXE01053 | 14 lines |
TOPIC | 3130.0 | UNIX V4.0 compatibility |
| 3130.1 | Thu Aug 01 1996 07:29 | No known issues with Digital UNIX 4.0 rev 383 or higher | 48 lines |
TOPIC | 3131.0 | COBOL TO PASCAL : Integer |
| 3131.3 | Thu Aug 01 1996 09:03 | Here are the results I get with VAX COBOL V5.3-42 | 89 lines |
TOPIC | 3132.0 | Problem with file definition/indexes |
| 3132.1 | Thu Aug 01 1996 17:02 | Segmented keys in FDL but not in COBOL source | 18 lines |
TOPIC | 3133.0 | ACCVIO depending on image size ? |
| 3133.1 | Tue Aug 20 1996 17:14 | Make sure the latest COBOL RTL is installed on the V7.0 system | 7 lines |
TOPIC | 3136.0 | V2.2 unix sort problem |
| 3136.2 | Thu Aug 29 1996 15:51 | I could not duplicate the reported problem | 139 lines |
TOPIC | 3138.0 | debugger problem |
| 3138.9 | Wed Aug 28 1996 23:11 | New DEBUG is in field test now | 9 lines |
TOPIC | 3139.0 | Procobol from HPUX to Alpha OVMS...Issues ? |
| 3139.1 | Thu Aug 29 1996 08:24 | See "Porting to DEC COBOL from Other Compilers" - V2.3 User Manual | 42 lines |
TOPIC | 3140.0 | Status 39, open index file after upgrade?? |
| 3140.1 | Fri Aug 30 1996 09:46 | You need COBOL/CHECK=NODUPLICATE_KEYS | 20 lines |
TOPIC | 3141.0 | SYS$GETTIM issue |
| 3141.1 | Fri Aug 30 1996 14:34 | Try DEC COBOL T2.4 FT1 | 9 lines |
| 3141.3 | Tue Sep 03 1996 20:09 | /ALIGN and mixing C and COBOL | 100 lines |
| 3141.5 | Wed Sep 04 1996 06:55 | List of 32 bug fixes (since V2.3-793) in V2.4 | 188 lines |
| 3141.7 | Wed Sep 04 1996 17:12 | Example with *DC [END-]SET | 31 lines |
TOPIC | 3142.0 | Problem with MOVE of S9(8)V99 to S9(9)V99 COMP-3 field |
| 3142.1 | Mon Sep 02 1996 01:40 | Try /NOOPT/CHECK; Try T2.4-853 | 42 lines |
TOPIC | 3144.0 | %COB-F-CLOSE_ERROR, Should have been trapped. |
| 3144.1 | Thu Sep 05 1996 08:02 | Reasons %COB-F-CLOSE_ERROR might not be trapped | 64 lines |
| 3144.3 | Fri Sep 06 1996 07:22 | Customer may have encountered a known V2.2 problem | 17 lines |
TOPIC | 3145.0 | Can use of floating point registers be supressed? |
| 3145.1 | Fri Sep 06 1996 09:42 | Use COBOL/WARNINGS=ALL with DEC COBOL V2.3-831 or higher | 25 lines |
TOPIC | 3146.0 | PICREQ +more using RMS-STS as WS name, Alpha only? |
| 3146.1 | Mon Sep 09 1996 07:15 | I can not get the program in .0 to compile with VAX COBOL | 41 lines |
| 3146.4 | Tue Sep 10 1996 08:04 | Documented difference between DEC COBOL and VAX COBOL | 41 lines |
TOPIC | 3148.0 | GLOBAL section usage of Alpha system |
| 3148.2 | Fri Sep 13 1996 07:07 | From VMSNOTES note 1503 | 38 lines |
TOPIC | 3149.0 | First DISPLAY AT LINE +nn different on VAX Cobol and DEC COBOL V2.2 |
| 3149.1 | Mon Sep 16 1996 07:31 | Documented difference between DEC COBOL and VAX COBOL | 14 lines |
TOPIC | 3150.0 | File status 02 with /stand=v3 |
| 3150.4 | Thu Sep 19 1996 08:01 | /STA=V3 and /STA=85 in VAX COBOL and DEC COBOL | 42 lines |
| 3150.6 | Thu Sep 19 1996 18:21 | No plans to change the behavior of /STA=V3 in VAX COBOL | 9 lines |
TOPIC | 3152.0 | Picture still limited to 65535 ? |
| 3152.1 | Mon Sep 30 1996 13:16 | There are no current plans to increase this limit | 14 lines |
TOPIC | 3153.0 | Informix from where?? |
| 3153.1 | Fri Oct 04 1996 11:59 | The DEC COBOL SPD has the Informix ordering details | 52 lines |
TOPIC | 3154.0 | COBOL & 64 bit addresses |
| 3154.1 | Tue Oct 08 1996 07:25 | DEC COBOL supports 64-bit addresses on Digital UNIX | 7 lines |
TOPIC | 3156.0 | Once again about Floating point registers |
| 3156.1 | Fri Oct 11 1996 09:25 | Use DEC COBOL V2.4 /WARNINGS=ALL - look for INTERMED diag | 18 lines |
TOPIC | 3157.0 | Customer info request via Reader's Comment Internet |
| 3157.2 | Mon Oct 14 1996 14:21 | Fixed with DEC COBOL V2.4 | 8 lines |
TOPIC | 3158.0 | RMS-RUJ problem on OpenVMS ALpha |
| 3158.1 | Tue Oct 15 1996 06:56 | Has the program run successfully on OpenVMS Alpha? | 5 lines |
| 3158.3 | Tue Oct 15 1996 10:03 | RU journaling is working OK for them except for this clause? | 10 lines |
| 3158.5 | Tue Oct 15 1996 10:30 | You should report this in VMSZOO::RMS_OPENVMS | 295 lines |
| 3158.7 | Tue Oct 15 1996 17:56 | Which file ORGANIZATION is the customer using? | 8 lines |
| 3158.9 | Wed Oct 16 1996 06:40 | The latest kit shows the RMS Journaling difference | 4 lines |
| 3158.10 | Wed Oct 16 1996 07:01 | .8 example results | 63 lines |
TOPIC | 3159.0 | Display with conversion?? |
| 3159.1 | Tue Oct 15 1996 11:12 | DISPLAY WITH CONVERSION extension | 12 lines |
TOPIC | 3160.0 | Year 2000 ? |
| 3160.1 | Wed Oct 23 1996 06:23 | See DEC COBOL V2.3 User Manual Chapter 1 | 29 lines |
| 3160.6 | Thu Feb 20 1997 12:18 | TIMA article | 183 lines |
TOPIC | 3161.0 | Same program. Different behavior on Vax or Axp |
| 3161.1 | Thu Oct 24 1996 13:05 | DEC COBOL and /CHECK=DECIMAL | 10 lines |
| 3161.2 | Fri Nov 01 1996 17:20 | QAR answer | 24 lines |
TOPIC | 3162.0 | Compiler not reporting the exact line error?!!! |
| 3162.2 | Fri Oct 25 1996 06:53 | Improvements in OpenVMS Alpha V7.0 DEBUG | 3 lines |
| 3162.3 | Fri Oct 25 1996 16:14 | Try the OpenVMS Alpha V7.0 debugger | 16 lines |
TOPIC | 3163.0 | Error number 00000004 ? |
| 3163.1 | Fri Oct 25 1996 16:13 | Try DEC COBOL V2.4 (compiler and RTL) | 21 lines |
| 3163.4 | Mon Oct 28 1996 09:26 | I get the same results with VAX COBOL and DEC COBOL | 12 lines |
TOPIC | 3164.0 | ACCVIO on VAX COBOL compile |
| 3164.1 | Mon Oct 28 1996 05:15 | Try VAX COBOL V5.3 - see note 2963 | 13 lines |
TOPIC | 3165.0 | VAX COBOL, OpenVMS VAX 7.0, doesn't seem to step correctly now |
| 3165.4 | Tue Oct 29 1996 11:17 | It is not yet know what is causing this difference | 19 lines |
| 3165.5 | Tue Oct 29 1996 11:20 | We do not yet know if a VAX COBOL fix is needed | 8 lines |
| 3165.8 | Mon Nov 04 1996 15:16 | DEBUG appears to have changed how it interprets the DSTs | 8 lines |
TOPIC | 3166.0 | How can we change the record attribute from RWCS? |
| 3166.1 | Tue Oct 29 1996 06:08 | Use COBOL/NOVFC with DEC COBOL | 26 lines |
| 3166.3 | Wed Oct 30 1996 04:36 | COBOL/NOVFC not supported by VAX COBOL | 12 lines |
TOPIC | 3167.0 | ALPHA MIGRATION PROBLEM ? |
| 3167.2 | Tue Oct 29 1996 11:23 | See DEC COBOL V2.3 User Manual - Compatibility Appendix | 8 lines |
TOPIC | 3168.0 | file size limit in DEC Cobol ? |
| 3168.2 | Wed Oct 30 1996 11:17 | 70 bug fixes since DEC COBOL V2.2 | 16 lines |
| 3168.4 | Fri Nov 08 1996 10:53 | Can you duplicate the customer problem on your system? | 9 lines |
| 3168.6 | Fri Nov 08 1996 12:44 | Do you have a program which fails on YOUR system w/ V2.4? | 19 lines |
| 3168.8 | Thu Nov 14 1996 17:17 | Input data file needed | 11 lines |
| 3168.11 | Mon Nov 18 1996 09:54 | RMS special registers now on Digital UNIX | 4 lines |
| 3168.13 | Mon Nov 18 1996 15:51 | Customer program reports invalid decimal data | 68 lines |
TOPIC | 3170.0 | Some questions about DEC Cobol-V2.* |
| 3170.1 | Thu Oct 31 1996 08:14 | ASSIGN TO literal length | 30 lines |
| 3170.4 | Wed Nov 06 1996 13:25 | Max file spec length is 255 characters | 32 lines |
| 3170.6 | Wed Nov 13 1996 13:42 | 280 character literal not supported | 46 lines |
TOPIC | 3171.0 | Oracle, ProCobol MF Cobol barfing |
| 3171.1 | Fri Nov 15 1996 05:19 | Use CSC32::COBOL2 | 4 lines |
TOPIC | 3172.0 | MF-Cobol ld: Error: Undefined: hashtb |
| 3172.1 | Mon Nov 18 1996 09:52 | Post MF COBOL/2 questions in CSC32::COBOL2 | 0 lines |
TOPIC | 3174.0 | Announcing VAX COBOL V5.4 |
| 3174.3 | Wed Jan 29 1997 18:33 | VAX COBOL V5.4 | 90 lines |
| 3174.3 | Tue Feb 04 1997 17:42 | VAX COBOL V5.4 SSB | 90 lines |
| 3174.4 | Sat Feb 01 1997 09:09 | VAX COBOL V5.4 (ftp.digital.com) | 92 lines |
| 3174.4 | Mon Feb 03 1997 19:34 | VAX COBOL V5.4 with corrected IVP | 10 lines |
| 3174.4 | Sun Feb 09 1997 06:44 | VAX COBOL V5.4 (ftp.digital.com) | 94 lines |
TOPIC | 3175.0 | HIGH-VALUES comparison fails for PIC S9(4) |
| 3175.1 | Wed Nov 20 1996 14:19 | Compile DEC COBOL with /CHECK=DECIMAL | 13 lines |
| 3175.2 | Wed Nov 20 1996 19:05 | Results with Micro Focus COBOL | 14 lines |
| 3175.6 | Thu Nov 21 1996 06:17 | HELP COBOL/CHECK has more details | 95 lines |
| 3175.7 | Thu Nov 21 1996 06:21 | Also see CLT::DEC_COBOL_IFT note 489 | 5 lines |
| 3175.10 | Fri Nov 22 1996 07:49 | See VC V5.0 RM 6.6.1.2 bullet 1 | 56 lines |
| 3175.12 | Fri Nov 22 1996 09:49 | Numeric operations on invalid decimal data are undefined | 11 lines |
| 3175.15 | Fri Nov 22 1996 11:57 | /CHECK=DECIMAL versus VAX instruction set | 8 lines |
TOPIC | 3176.0 | GEM-F-ASSERTION from FETCH w/implied rec-name? |
| 3176.1 | Mon Dec 09 1996 21:09 | Try DEC COBOL V2.4 | 14 lines |
TOPIC | 3177.0 | COBOL and CDDSHR again. |
| 3177.1 | Tue Dec 10 1996 07:10 | CDD is installed but not started on your system | 34 lines |
TOPIC | 3178.0 | Test problem. Gives a wrong result on AXP. |
| 3178.2 | Thu Dec 12 1996 08:33 | Compile with program with DEC COBOL /CHECK=DECIMAL | 4 lines |
| 3178.4 | Thu Dec 12 1996 09:31 | More on reason for /CONVERT=LEADING_BLANKS | 42 lines |
TOPIC | 3179.0 | Alpha Migration |
| 3179.1 | Mon Dec 16 1996 05:42 | /STANDARD=V3 migration issues | 49 lines |
| 3179.3 | Tue Dec 17 1996 06:01 | EXIT PROGRAM and /STANDARD=85 | 15 lines |
TOPIC | 3182.0 | Error sorting a huge file |
| 3182.1 | Thu Jan 09 1997 10:48 | See CLT::DEC_COBOL_IFT note 559 | 0 lines |
| 3182.3 | Thu Jan 09 1997 13:11 | VAX/DEC COBOL and multiple SORT/MERGE workfiles | 13 lines |
TOPIC | 3183.0 | Round, debug, missing virtual decimal point?? |
| 3183.3 | Tue Jan 14 1997 09:34 | Post DEBUG ACCVIO in TURRIS::DEBUG | 3 lines |
TOPIC | 3184.0 | %COB-F-INVALID_FNAME ?? |
| 3184.1 | Tue Jan 14 1997 11:22 | Does the application try to do ACCEPT in a batch job? | 14 lines |
| 3184.3 | Tue Jan 14 1997 12:23 | Upgrade to DEC COBOL V2.4 | 9 lines |
TOPIC | 3185.0 | Old bug re-service -LINE PLUS 0 |
| 3185.1 | Thu Jan 16 1997 06:20 | Make sure they are using the V5.3-42 compiler | 13 lines |
| 3185.4 | Wed Jan 29 1997 08:38 | What we need to make progress evaluating this difference | 57 lines |
| 3185.7 | Wed Jan 29 1997 11:26 | X40Q00022 QA tests still run successfully 9 years later | 13 lines |
TOPIC | 3186.0 | Why a READ_WRITE transaction on CDD during compilation |
| 3186.3 | Sun Jan 19 1997 06:25 | CDD$CREATE_HISTORY and other CDD$ calls | 16 lines |
| 3186.5 | Sun Jan 19 1997 10:37 | DEC/VAX COBOL compilers do not directly issue Rdb transactions | 14 lines |
| 3186.7 | Sun Jan 19 1997 14:24 | DEC COBOL V2.4 improved support for CDD | 22 lines |
TOPIC | 3187.0 | How does COBOL tell a MAIN from subroutine (called program) |
| 3187.1 | Wed Jan 22 1997 12:26 | More on LIB$INITIALIZE | 18 lines |
TOPIC | 3188.0 | OpenVMS VAX 7.1 and Cobol 5.3? |
| 3188.1 | Mon Jan 20 1997 08:36 | Recent testing of VAX COBOL T5.4 FT1 on OpenVMS VAX G7.1 | 21 lines |
TOPIC | 3190.0 | link error with ivp-DEC Cobol 2.3 |
| 3190.1 | Tue Jan 28 1997 16:35 | DIGITAL UNIX 3.2c versus 3.2d | 20 lines |
TOPIC | 3193.0 | Default current/check=all, occurs, decinv?? |
| 3193.1 | Wed Feb 05 1997 06:21 | More info on /CHECK=DECIMAL | 48 lines |
| 3193.3 | Wed Feb 05 1997 12:10 | See VAX/DEC COBOL User Manual (p. 5-18/-19) | 18 lines |
TOPIC | 3194.0 | Alignment error or bug with Forms? |
| 3194.4 | Mon Feb 10 1997 07:09 | MOVE CORRESPONDING? | 64 lines |
TOPIC | 3195.0 | 248 limit to EXTERNAL records? |
| 3195.1 | Fri Feb 07 1997 10:57 | See VAX COBOL User Manual - Appendix A-1 | 9 lines |
TOPIC | 3196.0 | COBOL V5.2-35 IVP Failes |
| 3196.1 | Mon Feb 10 1997 11:38 | VAX COBOL V5.2 is no longer supported | 6 lines |
| 3196.5 | Tue Feb 11 1997 06:45 | SELECT OPTIONAL is being tested with "COBOL$IVP.LIS.30000" | 17 lines |
TOPIC | 3197.0 | Upgrade selling advice required |
| 3197.1 | Tue Feb 11 1997 16:29 | Other reasons to upgrade to VAX COBOL V5.4 | 27 lines |
TOPIC | 3200.0 | Still question about ALIGNMENT w FORMS |
| 3200.2 | Thu Feb 13 1997 11:17 | More on DEC COBOL V2.4 and /ALIGN=PADDING | 68 lines |
| 3200.5 | Wed Feb 19 1997 08:29 | You need to compile COBOL/ALIGN=PADDING | 10 lines |
| 3200.9 | Wed Feb 19 1997 10:31 | See notes 2751 and 2833 | 30 lines |
TOPIC | 3202.0 | Reformat utility from a Unix Makefile |
| 3202.2 | Wed Feb 19 1997 16:26 | % reformat < r.in | 18 lines |
TOPIC | 3203.0 | Vesting problem with VAX COBOL |
| 3203.3 | Fri Feb 21 1997 06:28 | See note 2175 | 1 lines |
TOPIC | 3204.0 | Which VAX/VMS Cobol Compiler Year 2000 compliant ? |
| 3204.1 | Sat Feb 22 1997 06:18 | VAX COBOL V5.4 | 14 lines |
TOPIC | 3205.0 | ACCVIO in DEC$COBRTL |
| 3205.5 | Sun Mar 02 1997 22:49 | Try V2.4 | 12 lines |
TOPIC | 3209.0 | Where can I find the fix kit V2.3-827? |
| 3209.1 | Tue Mar 04 1997 06:04 | See CLT::DEC_COBOL_IFT notes 2.47 and 2.51 | 6 lines |
TOPIC | 3210.0 | DEC COBOL cannot read all the records..... |
| 3210.11 | Fri Mar 07 1997 05:59 | On the wishlist | 11 lines |
TOPIC | 3211.0 | Sun Mar 09 1997 14:06 | I/O problems with OpenVMS Alpha V7.x | 34 lines |
| 3211.1 | Mon Mar 10 1997 15:59 | Don't use APPLY PREALLOCATION/EXTENSION on OpenVMS Alpha V7.1 | 15 lines |
| 3211.2 | Tue Mar 11 1997 08:25 | Update sent on case | 87 lines |
| 3211.4 | Mon Jun 02 1997 17:01 | TIMA kit - ALPRMS01_071 | 9 lines |
TOPIC | 3212.0 | Question on COMP-1, 2 and /float=D, G |
| 3212.1 | Mon Mar 10 1997 06:48 | Alpha floating point details | 37 lines |
| 3212.3 | Mon Mar 10 1997 11:15 | Quotes from 1992 Alpha Architecture Handbook | 13 lines |
TOPIC | 3214.0 | reserved operand fault |
| 3214.1 | Wed Mar 12 1997 15:58 | Fernando will request the customer source | 45 lines |
| 3214.4 | Tue Mar 18 1997 09:43 | Explanation of how DEC COBOL handles invalid decimal data | 40 lines |
TOPIC | 3215.0 | Can Micro Focus COBOL run on AlphaServer with Digital UNIX? |
| 3215.1 | Thu Mar 13 1997 09:07 | Try CSC32::COBOL2 | 1 lines |
TOPIC | 3216.0 | Read alternate key with duplicates |
| 3216.4 | Tue Mar 18 1997 00:47 | More ideas | 18 lines |
TOPIC | 3217.0 | Rounding problem with IEEE floats |
| 3217.2 | Fri Mar 14 1997 13:33 | From CLT::DEC_COBOL_IFT 581 | 96 lines |
| 3217.3 | Fri Mar 14 1997 13:45 | see note 3212 | 4 lines |
| 3217.8 | Tue Mar 18 1997 07:30 | COMPUTE is the only temporary workaround identified so far | 17 lines |
| 3217.9 | Wed Mar 19 1997 15:39 | We are testing a potential fix | 48 lines |
| 3217.9 | Thu Mar 20 1997 09:22 | We are testing a potential fix | 64 lines |
| 3217.10 | Mon Mar 24 1997 07:10 | Update sent on case - fixed with 2.4-906 compiler | 73 lines |
| 3217.11 | Tue Apr 22 1997 08:12 | See CLT::DEC_COBOL_IFT note 2.58 for a kit with the fix | 0 lines |
TOPIC | 3218.0 | linage file problem under DEC COBOL on Alpha |
| 3218.1 | Wed Mar 19 1997 08:20 | Temporary workaround - compile DEC COBOL /NOVFC | 12 lines |
TOPIC | 3219.0 | Example to convert to a YYYYMMDD date. |
| 3219.1 | Tue Mar 25 1997 07:41 | Use FUNCTION CURRENT-DATE | 44 lines |
TOPIC | 3220.0 | help with creating/reading tapes on Digital UNIX |
| 3220.1 | Wed Mar 26 1997 18:31 | ltf command line? | 3 lines |
| 3220.3 | Thu Mar 27 1997 14:29 | DEC COBOL RTL supports ANSI labeled tapes initialized with ltf | 19 lines |
TOPIC | 3221.0 | Cobol incorrectly defines labels for Debugger use |
| 3221.1 | Sat Mar 29 1997 07:35 | Debug break behavior duplicated with VAX COBOL V5.4 | 27 lines |
| 3221.3 | Wed Apr 02 1997 16:32 | Update sent on case | 51 lines |
TOPIC | 3223.0 | VAX/ALPHA Migration questions... |
| 3223.1 | Sat Apr 05 1997 10:17 | Possible migration issues | 125 lines |
| 3223.2 | Mon Apr 07 1997 13:04 | Some reasons for upgrading to a supported VAX COBOL configuration | 27 lines |
TOPIC | 3224.0 | Color Support? |
| 3224.1 | Mon Apr 07 1997 07:41 | X/Open SCREEN SECTION - FOREGROUND/BACKGROUND-COLOR | 78 lines |
| 3224.2 | Wed Apr 09 1997 09:20 | ANSI Standard color sequences | 6 lines |
TOPIC | 3225.0 | Keynotfou, accessing remote dictionary?? |
| 3225.1 | Mon Apr 07 1997 09:17 | Some remote access notes from the CDD release notes | 105 lines |
TOPIC | 3226.0 | CALL > 255 arguments? |
| 3226.1 | Sun Apr 13 1997 16:02 | I'll add this to the DEC COBOL wishlist | 7 lines |
TOPIC | 3227.0 | LIB$ESTABLISH and ON SIZE ERROR |
| 3227.3 | Tue Apr 15 1997 18:27 | Update sent on case | 71 lines |
| 3227.4 | Wed Apr 16 1997 08:50 | Fixed with 2.4-909 compiler | 46 lines |
| 3227.5 | Tue Apr 22 1997 08:12 | See CLT::DEC_COBOL_IFT note 2.58 for a kit with the fix | 0 lines |
TOPIC | 3228.0 | Forcing a deliberate data exception on the Alpha |
| 3228.3 | Tue Apr 15 1997 16:09 | Is the customer using USAGE DISPLAY? | 13 lines |
| 3228.5 | Tue Apr 15 1997 17:47 | PIC 9 does what you need | 29 lines |
| 3228.6 | Wed Apr 16 1997 13:44 | Revised program to force invalid decimal data | 23 lines |
TOPIC | 3229.0 | NUMLONG error with COBOL/CDD on AXP using huge init. values |
| 3229.2 | Thu Apr 17 1997 07:08 | Could not reproduce with DEC COBOL V2.4 and CDD V5.3 | 21 lines |
| 3229.5 | Thu Apr 17 1997 10:16 | TEST.LIS with DEC COBOL V2.4 | 68 lines |
| 3229.8 | Thu Apr 17 1997 12:09 | I used the script from .0 | 3 lines |
| 3229.10 | Thu Apr 17 1997 12:50 | Are you getting a failure with CDD V5.3? | 6 lines |
| 3229.12 | Thu Apr 17 1997 14:54 | I think the version of CDD may make a difference | 15 lines |
| 3229.13 | Thu Apr 17 1997 18:18 | Did the suggestions Bill made in .4 help? | 2 lines |
| 3229.16 | Thu May 01 1997 09:27 | No reports yet of this problem with CDD V5.3 | 24 lines |
| 3229.17 | Tue May 06 1997 14:00 | Update sent on case | 152 lines |
TOPIC | 3230.0 | any plan to support big-endian/little-endian |
| 3230.1 | Thu Apr 17 1997 07:15 | No current plans for big endian binary data support in DEC COBOL | 8 lines |
TOPIC | 3231.0 | procobol -> accvio at runtime? |
| 3231.1 | Thu Apr 17 1997 18:10 | RMS special registers? | 14 lines |
TOPIC | 3232.0 | Alpha OpenVMS 7.1 and COBOL 2.4 |
| 3232.1 | Fri Apr 18 1997 17:46 | See note 3211 | 0 lines |
| 3232.3 | Thu Apr 24 1997 15:47 | Try the DEC COBOL 2.4-909 bug fix kit | 29 lines |
TOPIC | 3234.0 | /check=decimal switch producing stange results |
| 3234.1 | Thu Apr 24 1997 08:32 | Is det-line-type really ''? | 68 lines |
| 3234.5 | Thu Apr 24 1997 12:53 | Check variable values with DISPLAY before the IF | 6 lines |
TOPIC | 3235.0 | defining Global variarble in COBOL? |
| 3235.1 | Thu Apr 24 1997 07:14 | Use CALL or EXTERNAL | 13 lines |
| 3235.3 | Fri Apr 25 1997 10:44 | Use the common reference model rather than globalref | 40 lines |
| 3235.6 | Mon Apr 28 1997 07:59 | .3 works fine for VAX COBOL with VAX C | 5 lines |
TOPIC | 3236.0 | 5.4/VAX 7.1/LSE : INSFAIL (%DCL-W-NOPAREN) |
| 3236.1 | Tue Apr 29 1997 12:55 | LSE update portion of installation procedure to be removed | 9 lines |
TOPIC | 3237.0 | MULTIPLY GIVING gives incorrect results |
| 3237.3 | Wed Apr 30 1997 21:54 | We'll post a note here when we have a compiler fix | 14 lines |
| 3237.5 | Thu May 01 1997 16:16 | Compiler fix testing in progress | 3 lines |
| 3237.7 | Fri May 02 1997 07:58 | Fixed with 2.4-913 compiler | 13 lines |
| 3237.9 | Tue May 06 1997 07:57 | 2.4-914 | 72 lines |
TOPIC | 3238.0 | request for compiler error list |
| 3238.1 | Thu May 01 1997 11:49 | Error message information | 17 lines |
TOPIC | 3242.0 | COBOL V2.4 ... executables has increased by 20% |
| 3242.1 | Tue May 13 1997 16:05 | Our measurements of object size changes (V2.3, V2.4, /NOOPT) | 28 lines |
| 3242.3 | Fri May 23 1997 07:08 | We could try one of the .COB files | 14 lines |
TOPIC | 3243.0 | DISPLAY differences on VAX and Alpha |
| 3243.2 | Fri May 23 1997 07:02 | Documented difference between DEC COBOL and VAX COBOL | 2 lines |
TOPIC | 3244.0 | INDEXED READ differences on VAX and ALPHA |
| 3244.1 | Wed May 28 1997 13:02 | We need a program example we can compile | 5 lines |
| 3244.3 | Wed May 28 1997 14:21 | GTVMS, SMGDSP, VKBD | 8 lines |
| 3244.5 | Wed May 28 1997 15:51 | Some info on the parser error recover to "next statement" | 13 lines |
TOPIC | 3245.0 | insufficient virtual memory |
| 3245.1 | Sat May 31 1997 09:57 | Memory tuning info in the DEC COBOL User Manual | 13 lines |
TOPIC | 3246.0 | Any advice about this behavior after 10K patch installed |
| 3246.1 | Wed Jun 04 1997 07:29 | Some details on VAX COBOL V5.3 and V5.4 | 21 lines |
TOPIC | 3247.0 | VAX COBOL V5.4- OPENVMS V7.1 COMPATABILITY |
| 3247.1 | Wed Jun 04 1997 07:38 | See notes 3165 and 3236 | 23 lines |
TOPIC | 3248.0 | Cobol ccomplie error |
| 3248.1 | Thu Jun 05 1997 07:13 | Possibly 2 different source problems to correct here | 23 lines |
TOPIC | 3249.0 | Group Initialization problem |
| 3249.2 | Thu Jun 05 1997 16:56 | RECORD IS VARYING gives consistent results | 46 lines |
TOPIC | 3250.0 | Access violation when a Cobol PRG opens a RMS file |
| 3250.1 | Fri Jun 06 1997 10:42 | VAX COBOL V5.3-40 has a known problem - ACCVIO on OPEN | 13 lines |