TOPIC | 319.0 | Internal SCSI cable lenght? |
| 319.3 | Fri May 12 1995 10:19 | Your stretching it one meter too much | 4 lines |
TOPIC | 326.0 | Power Supply spec. on RM SABLE |
| 326.5 | Wed Aug 10 1994 10:33 | Pointer for eng spec | 3 lines |
TOPIC | 582.0 | Power question? |
| 582.1 | Wed Oct 05 1994 11:56 | Sounds like you have some early rev supplies | 13 lines |
TOPIC | 616.0 | Strange power-up problem on 2100-600 w/ J3 removed |
| 616.1 | Thu Oct 13 1994 15:51 | You must have had 1 of the power supplies disconnected | 10 lines |
| 616.4 | Wed Oct 19 1994 11:14 | OK, try this | 7 lines |
| 616.6 | Tue Oct 25 1994 20:07 | More things to narrow it down further | 16 lines |
| 616.8 | Wed Oct 26 1994 08:34 | Try the replacing the power supply control cable | 11 lines |
TOPIC | 698.0 | RM questions (rackmount) |
| 698.7 | Mon Jan 16 1995 16:20 | Is it warm in the room? | 8 lines |
TOPIC | 798.0 | EMI/RFI info needed |
| 798.1 | Thu Dec 01 1994 14:06 | Best contact us (CSS ) offline on this | 3 lines |
TOPIC | 984.0 | high level noise on axp 2100 rackmount |
| 984.2 | Thu Feb 02 1995 16:07 | See notes 698.6, 7 | 3 lines |
TOPIC | 1107.0 | Dual redundant power suplly monitoring in 600MP? |
| 1107.1 | Wed Mar 15 1995 08:07 | No way to remotely monitor with present configuration | 16 lines |
| 1107.3 | Thu Mar 16 1995 09:13 | Ok, here's where the signals can be accessed | 20 lines |
TOPIC | 1137.0 | RAID 5 / SWXCR problem? |
| 1137.5 | Wed Mar 22 1995 08:33 | Did you try running SRLMGR instead of SWXCRMGR? | 4 lines |
TOPIC | 1174.0 | Additional Power Supply needed? |
| 1174.1 | Wed Apr 05 1995 09:02 | This is unusual | 23 lines |
| 1174.3 | Thu Apr 06 1995 08:57 | One supply can drive a fully loaded system | 7 lines |
| 1174.9 | Mon Apr 10 1995 09:52 | Is there an isolation transformer | 6 lines |
| 1174.11 | Mon Apr 10 1995 10:27 | What specific systems have failed | 13 lines |
| 1174.13 | Tue Apr 11 1995 09:48 | Be careful where you place this resistor. | 13 lines |
TOPIC | 1308.0 | 2100 4/275 rack Startup current |
| 1308.1 | Fri Jun 02 1995 16:59 | Inrush current? | 5 lines |
TOPIC | 1407.0 | Internet: Power supply complaint |
| 1407.1 | Mon Jul 10 1995 15:31 | Problem Identified as MOV (Metal Oxide Varistor) | 19 lines |
TOPIC | 1487.0 | Installing 6.1VMS to an RZ28M 6.2 Works fine. |
| 1487.1 | Mon Aug 07 1995 08:58 | Sounds Like there's no terminator on the back of the unit | 3 lines |
TOPIC | 1499.0 | Thermal trip on Rackmount 2100 ? |
| 1499.1 | Wed Aug 09 1995 15:55 | It's in the power supply | 8 lines |
TOPIC | 1519.0 | Too many power supply failures!!! |
| 1519.8 | Mon Aug 28 1995 17:47 | Reply .5 is irrelevant | 3 lines |
| 1519.18 | Wed Nov 29 1995 08:43 | Sounds like a Fan Tach | 12 lines |
TOPIC | 1668.0 | Rackmount power supply |
| 1668.1 | Mon Oct 30 1995 08:27 | MOV problem, fixed in B03 units | 7 lines |
TOPIC | 1836.0 | 2100 RM power shutdown |
| 1836.2 | Wed Jan 03 1996 16:05 | See Notes 1519.17-19 | 3 lines |
TOPIC | 2002.0 | T2 - PCI Address Parity Error? |
| 2002.1 | Tue Mar 19 1996 08:03 | Can you give us some more details? | 10 lines |
TOPIC | 2185.0 | Console out of focus with extension cable |
| 2185.1 | Fri Jun 07 1996 12:24 | What is the resolution | 5 lines |