TOPIC | 1.0 | WELCOME |
| 1.1 | Wed Nov 17 1993 10:55 | new "Regime" trying to improve on a good thing | 16 lines |
TOPIC | 3.0 | Wed Nov 17 1993 11:00 | Suggestion/comment Box | 7 lines |
TOPIC | 4.0 | Wed Sep 29 1993 16:02 | CSA information | 5 lines |
| 4.5 | Tue Nov 02 1993 11:04 | PTC thermistors are CSA approvable | 9 lines |
TOPIC | 5.0 | Fri Oct 15 1993 12:15 | UL information | 4 lines |
TOPIC | 6.0 | Wed Sep 29 1993 15:50 | Flammability discussions | 4 lines |
TOPIC | 7.0 | Fri Oct 15 1993 12:20 | Wiring and power cords | 4 lines |
| 7.5 | Tue Aug 15 1989 16:38 | One verdict | 23 lines |
TOPIC | 9.0 | Laser Requirement Guidelines |
| 9.3 | Wed Sep 29 1993 15:57 | New address for CDRH | 38 lines |
TOPIC | 10.0 | Wed Sep 29 1993 16:07 | X-Ray discussions | 3 lines |
TOPIC | 13.0 | Designing Product Safety in |
| 13.2 | Fri Jan 19 1990 10:24 | Designing for stability. Memo from Bob Johnson | 98 lines |
TOPIC | 14.0 | Fri Oct 15 1993 12:18 | Telecom issues and requirements | 5 lines |
TOPIC | 17.0 | Wed Sep 29 1993 15:53 | Direct Plug-in and "Brick" supplies | 4 lines |
TOPIC | 46.0 | Fri Aug 10 1990 14:52 | GS Mark for Components | 125 lines |
TOPIC | 48.0 | Fri Nov 02 1990 14:20 | Canadian Electrical Code | 50 lines |
TOPIC | 61.0 | discussions on Medical equipment |
| 61.1 | Tue Oct 27 1992 08:23 | depends on proximity of patient! | 13 lines |
| 61.5 | Wed Mar 24 1993 09:56 | Relevant standards as of 11/92 | 36 lines |
| 61.6 | Wed Mar 24 1993 10:01 | Issues encountered during an actual submittal | 199 lines |
| 61.7 | Wed Mar 24 1993 10:02 | More findings | 49 lines |
| 61.8 | Wed Mar 24 1993 10:09 | additional insight | 65 lines |
| 61.9 | Wed Mar 24 1993 10:09 | Sample test format | 4330 lines |
| 61.10 | Wed Mar 24 1993 10:11 | sample report format | 825 lines |
TOPIC | 64.0 | Small rear opening |
| 64.1 | Thu Dec 31 1992 09:52 | ignition source? | 3 lines |
| 64.3 | Wed Jan 06 1993 10:33 | Label is compliant in this application | 21 lines |
TOPIC | 67.0 | Fri Sep 10 1993 10:43 | Regulatory Standard Beyond North America | 7 lines |
| 67.1 | Fri Sep 10 1993 12:28 | Some accoustic and EMI | 17 lines |
| 67.2 | Wed Sep 29 1993 15:33 | Some IEC standards | 11 lines |
| 67.3 | Tue Dec 14 1993 10:55 | IEC 801 is EMI related | 8 lines |
TOPIC | 68.0 | Fri Sep 10 1993 10:39 | U.S. Regulatory Standards | 8 lines |
| 68.1 | Wed Sep 29 1993 15:31 | UL documents | 50 lines |
TOPIC | 69.0 | Fri Sep 10 1993 10:40 | Canadian Standards | 7 lines |
| 69.1 | Wed Sep 29 1993 15:16 | List from CSA | 26 lines |
| 69.2 | Tue Dec 14 1993 11:37 | CSA Communication accessories | 7 lines |
TOPIC | 70.0 | Wed Sep 29 1993 15:07 | Australian Standards | 7 lines |
| 70.1 | Tue May 02 1989 16:24 | Australia's version of IEC950 | 287 lines |
| 70.2 | Wed Sep 29 1993 15:09 | Standards as given by Allen Paull | 175 lines |
TOPIC | 72.0 | Fri Oct 01 1993 12:09 | European discussions | 3 lines |
TOPIC | 74.0 | Tue Oct 19 1993 08:54 | CSA Office Phone & Fax #'s | 18 lines |